Buffalo WS5600D2406-EU [34/67] Hard drive replacement in case of disk failure on drive 1 or drive 2

Buffalo WS5400D0404-EU [34/67] Hard drive replacement in case of disk failure on drive 1 or drive 2
34
To restore a Mirrored volume (RAID resynchronization):
(a) Right-click the volume labeled “Failed Redundancy and click Remove Mirror.
(b) When “Remove Mirror is displayed, select the drive with its status missing and click OK.
Note: Perform steps (a) and (b) for each volume that requires RAID resynchronization.
(c) Select the new volume where mirroring will be performed, then select Add Mirror.
(d) When Add Mirror” is displayed, select the drive where mirroring will be performed with the selected volume,
then click Add Mirror.
(e) When “Disk Management” is displayed, click OK.
Hard Drive Replacement in Case of Disk Failure on Drive 1 or Drive 2
1 Shut down the TeraStation.
2 WS5600D, WS5400D, WS5200D: Open the front cover with the included key.
3 Push the unlock button of the failed hard drive and swing the lock mechanism out.
4 Pull out the drive cartridge and remove it from the TeraStation.
5 Insert the new drive in the empty slot. Slide the drive in with the locking mechanism open.
6 Swing the lock back down until it clicks into place.
7 Close the front cover with the included key.
Press the power button on the TeraStation to turn it on.
Note: If drive 1 is being replaced, the red error LED will light up and “POST ERR: 00D9 Boot from HDD x will be
displayed on the LCD panel. Wait for the unit to reboot. When the reboot is finished, go on to step 8.
8 Open NAS Navigator2 by double-clicking the icon on the Windows desktop or in the Dock if you have a Mac.
9 Right-click on your TeraStations icon, then click Open Remote Desktop.
For Mac, click the TeraStation icon while holding down the control key, then click Open Remote Desktop.
10 Enter the username and password, then click OK. Windows Storage Server opens in the remote desktop.
Note: The default username and password are Administrator and “password”.
11 Click Launch RAID Builder from the Start menu of Windows Storage Server.
12 Select Repair the mirrored volume of the system area, check replaced hard drive, and click OK.