Buffalo WS5600D2406-EU [60/67] Errors and status

Buffalo WS5400D0804-EU [60/67] Errors and status
60
LINK SPEED
Note: When an Ethernet cable is
connected to LAN Port 2, “LINK
SPEED 2” is displayed.
LINK SPEED
No LINK
Not connected to network.
LINK SPEED
10Mbps
Connected at 10 Mbps.
LINK SPEED
100Mbps
Connected at 100 Mbps.
LINK SPEED
1000Mbps
Connected at 1000 Mbps full duplex.
Disk Space Used
HDD
USED
Bar graphs are shown to indicate the used
space for the C, D, E, and F internal drives of
the TeraStation. When a hard drive is full, it is
indicated by “^”.
Hostname/IP Address
WS5000xxx
192.168.11.150
Displays the hostname and IP address.
Calendar/Clock
DATE TIME
2012/1/1 11:11
Displays the date and time set in the
TeraStation.
Installed OS
Windows Storage Server
2012
Displays the OS installed on the TeraStation.
IP Address 2
NETWORK2
192.168.11.151
Displays the IP address of LAN port 2 when
an Ethernet cable is connected to LAN port 2.
Errors and Status
LCD Message Description Corrective Action
SYSTEM Error E11
Fan Failure
An error occurred in the fan speed.
Check that no foreign
objects or dust are
clogging the fan. If any
foreign objects or dust
are found, use a pair of
tweezers, air duster, or
other tool to remove
them. If the error is
displayed again, contact
Buffalo technical support
for assistance.
SYSTEM Error E12
Cooling Failure
A rise in the system temperature may have
exceeded the allowable safety value.
Do not place objects
in the area around the
TeraStation. Also, move
the TeraStation to a cool
location. Make sure that
the TeraStations fan is
working normally.
HDx Error E16
HDx Not Found
Unable to find hard drive X.
Hard drive X may be
disconnected or may
have failed. After shutting
down, reinstall the hard
drive.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive X was
removed from the RAID array.
Replace hard drive X.