y First, install the converter onto a carrier supplied with
the chassis:
Step 1- Unscrew and pull out the media converter board.
Step 2- Plug in the media board to any of the vacant slot.
Step 3- Fit the converter onto the carrier and use the screw
to secure it.
Monitoring the Converter through
Management Module
There is a management module that can control this media
converter through the chassis system, this media converter
can be controlled through Web Browser, SNMP and terminal
emulation program.
The management module will detect the default reset on the
DIP switches and display out the status, also the
management module can control the function through the
chassis system.
Содержание
- Base tx to 1000base sx lx media converter user s guide 1
- Installatio 2
- Introductio 2
- Product feature 2
- Specification 2
- Table of contents 2
- About media converter 3
- Ntroduction 3
- Eatures 4
- Roduct 4
- Connecting to power 5
- Installing in a chassis 5
- Nstallation 5
- Selecting a site for the equipment 5
- First install the converter onto a carrier supplied with the chassis 6
- Monitoring the converter through management module 6
- Led indicator 7
- Link pass through function 7
- Llcf link loss carry forward when a device connected to the converter and the tp line loss the link the converter s fiber will disconnect the link of transmit so that the other ends will know that there is a linkage error on this end and when the fiber line loss the link the converter s tp will disconnected and the other end will know that there is linkage problem exist there is a default llcf setting on this converter 7
- The led indicators give you instant feedback on status of the converter 7
- Llr link loss return when a device connected to the converter and the fiber line loss the link the converter s fiber will disconnect the link of transmit there is a switch to enable or disable the function of the media converter 8
- Switch 9
- Switch 2 llr when the switch was turned to on it means that the llr was enabled and off for disabled 9
- There is a two pin dip switch on the module which define as switch 1 and switch 2 switch 1 fiber mode switch when the switch was turned to on it means that the fiber was turned to forced mode and off for auto negotiation mode 9
- Pecifications 10
Похожие устройства
- KitchenAid Artisan 5KEK1522EER зеленое яблоко Инструкция по эксплуатации
- D-Link DMC-805G Инструкция по эксплуатации
- Gaggenau RC 289 Инструкция по эксплуатации
- KitchenAid Artisan 5KEK1522EFP морозный жемчуг Инструкция по эксплуатации
- Gaggenau RC 249 Инструкция по эксплуатации
- KitchenAid Artisan 5KEK1522EGA зеленое яблоко Инструкция по эксплуатации
- D-Link DMC-1530SC Инструкция по эксплуатации
- Gaggenau RC 282 Инструкция по эксплуатации
- KitchenAid Artisan 5KEK1522EMS серебряный медальон Инструкция по эксплуатации
- Gaggenau RC 242 Инструкция по эксплуатации
- D-Link DMC-1002 Инструкция по эксплуатации
- KitchenAid Artisan 5KEK1522EOB черный Инструкция по эксплуатации
- Gaggenau RC 200 Инструкция по эксплуатации
- D-Link DAS-4672 Инструкция по эксплуатации
- Bork U701 White Инструкция по эксплуатации
- Gaggenau RC 222 Инструкция по эксплуатации
- D-Link DAS-4192 Инструкция по эксплуатации
- Bork U801 Инструкция по эксплуатации
- D-Link DSL-2540U ANNEX B Инструкция по эксплуатации
- Gaggenau DF 461 Инструкция по эксплуатации
Скачать
Случайные обсуждения