Gigabyte S260-NF1 (rev. 100) Руководство пользователя онлайн [29/32] 534889

Gigabyte S260-NF1 (rev. 100) Руководство пользователя онлайн [29/32] 534889
- 31 - Western Digital NIC Conguration
set-ip 1 0 3.3.3.1 255.255.255.0 3.3.3.4 Port1
Congure the IP address of the rst Ethernet port.
Note: Refer to Appendix Fuji Prole Conguration for selecting different prole, Onyx boards are shipped with
default prole 0, which supports up to 8 drives. To test 12 drives, please select prole 1. It needs reboot after
prole changed.
It’s strongly recommended to check the Ethernet link status, PCIe link status and drives presented before
further operations.
show-version 1
Check the rmware version to make sure the rmware is up to date.
show-pcie 0xff
Check the PCIe link status and also the number of drives discovered.
show-port 0xff
Check the Ethernet link status.
show-present 0xff
Display the present of NVMe drives in bitmap concept. For example, 0x0000001E means there are drives at
slot#1, slot#2, slot#3 and slot#4.
show-drive 0xff
Display the drive details of each slot.

Похожие устройства