Suzuki BURGMAN AN650 (2003) [198/463] C22 ap sensor circuit malfunction

Содержание

Fl SYSTEM CVT SYSTE C22 AP SENSOR CIRCUIT MALFUNCTION DETECTED CONDITION Output voltage low or high 0 50 V Sensor voltage 4 85 V without the above range NOTE Note that atmospheric pressure caries depending on weather conditions as well as altitude Take that into consideration when inspecting voltage INSPECTION Remove the front box CZ Q 18 POSSIBLE CAUSE Clogged air passage with dust AP sensor circuit open or short AP sensor malfunction ECM malfunction