APC smart-ups smx750i [3/21] Inspect the package contents upon receipt notify the carrier and dealer if there is any damage
![APC smart-ups smx1000i [3/21] Inspect the package contents upon receipt notify the carrier and dealer if there is any damage](/views2/1159287/page3/bg3.png)
1Smart-UPS X 750/1000/1500 VA 120/230 Vac Rack-Mount 2U
Product Description
The APC
™
by Schneider Electric Smart-UPS
™
is a high performance uninterruptible power supply (UPS). The
UPS provides protection for electronic equipment from utility power blackouts, brownouts, sags, and surges, small
utility power fluctuations and large disturbances. The UPS also provides battery backup power for connected
equipment until utility power returns to safe levels or the batteries are fully discharged.
This user manual is available on the enclosed CD and on the APC by Schneider Electric Web site, www.apc.com.
Important Safety Messages
Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or
maintain it. The following special messages may appear throughout this manual or on the equipment to warn of
potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Caution product safety label indicates that a hazard exists that
can result in injury and product damage if the instructions are not followed.
The following safety messages may appear throughout this manual to warn of potential
hazards.
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there is any
damage.
Read the Safety Guide supplied with this unit before installing the UPS.
• Adhere to all local and national electrical codes.
• This UPS is intended for indoor use only.
• Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or
humidity.
• Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
• The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient
temperatures, poor quality utility power, and frequent short duration discharges will shorten battery life.
• Connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or
moderate injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage.
Содержание
- Operation manual 1
- Smart ups x uninterruptible power supply 1
- Caution 3
- Important safety messages 3
- Inspect the package contents upon receipt notify the carrier and dealer if there is any damage 3
- Product description 3
- Read the safety guide supplied with this unit before installing the ups 3
- Safety and general information 3
- Front panel features 4
- Product overview 4
- Rear panel features 4
- Environmental specifications 5
- External battery pack 5
- Humidity 5
- Installation 5
- Maximum elevation 5
- Network management card 5
- Specifications 5
- Temperature 5
- Basic connectors 6
- Caution 6
- Connect equipment to the ups 6
- Operation 6
- Apc by schneider 7
- Display panel 7
- Electric 7
- Menu general functions 7
- Overview 7
- Standard menus 7
- Using the display interface 7
- Advanced menus 8
- Menu general functions 8
- Configuration 9
- Function factory default options description 9
- General settings 9
- Start up settings 9
- Ups settings 9
- Controllable outlet groups 10
- Function factory default options description 10
- Overview 10
- Controllable outlet group s 2 ups outlets 11
- Model specific controllable outlet groups 11
- Smart ups x 750 1000 1500 va 120 230 vac rack mount 2u 11
- Va 120 230 vac 11
- Va 120 vac 11
- Using the controllable outlet groups and ups outlets 12
- Customize the controllable outlet groups and the ups outlets 13
- Function factory default options description 13
- Network management card settings 14
- Emergency power off 15
- Normally closed contacts 15
- Normally open contacts 15
- Overview 15
- Display interface leds flash sequentially 16
- Problem and possible cause solution 16
- The site wiring fault led illuminates the ups displays a fault message and emits a constant beeping sound 16
- The ups is operating on battery while connected to utility power 16
- The ups will not turn on or there is no output 16
- Troubleshooting 16
- Ups does not provide expected backup time 16
- Ups is emits intermittent beeps 16
- All leds are illuminated and the ups is plugged into a wall outlet 17
- Problem and possible cause solution 17
- The replace battery led is illuminated 17
- The ups displays a site wiring fault message 17
- A always disconnect the ups batteries before shipping the united states department of transportation dot and the international air transport association iata regulations require that ups batteries be disconnected before shipping the internal batteries may remain in the ups 18
- A note the model number and serial number and the date of purchase the model and serial numbers are located on the rear panel of the unit and are available through the lcd display on select models 18
- B call apc by schneider electric customer support and a technician will attempt to solve the problem over the phone if this is not possible the technician will issue a returned material authorization number rma 18
- C if the unit is under warranty the repairs are free 18
- D service procedures and returns may vary internationally refer to the apc by schneider electric web site for country specific instructions 18
- If the unit requires service do not return it to the dealer follow these steps 18
- Service 18
- Transport the unit 18
- Two year limited factory warranty 19
- 2013 990 3458c 21
- Apc by schneider electric worldwide customer support 21
Похожие устройства
- APC smart-ups smx1000i Инструкция по эксплуатации
- APC smart-ups smx1500rmi2u Инструкция по эксплуатации
- APC smart-ups sum1500rmxli2u Инструкция по эксплуатации
- APC smart-ups sum3000rmxli2u Инструкция по эксплуатации
- APC back-ups br1200gi Инструкция по эксплуатации
- APC smart-ups surt1000xli Инструкция по эксплуатации
- APC smart-ups srt6kxli Инструкция по эксплуатации
- APC smart-ups srt5kxli Инструкция по эксплуатации
- APC back-ups bx500ci Инструкция по эксплуатации
- APC smart-ups srt8kxli Инструкция по эксплуатации
- APC symmetra lx xr 8kva scalable to 16kva sya8k16ixr Инструкция по эксплуатации
- APC surgearrest pm8-rs Инструкция по эксплуатации
- APC smart-ups smc3000i Инструкция по эксплуатации
- APC bx650ci-rs+ power bank Инструкция по эксплуатации
- APC back-ups be700g-rs+ Инструкция по эксплуатации
- APC back-ups bx1400ui Инструкция по эксплуатации
- APC back-ups bx700ui Инструкция по эксплуатации
- APC back-ups bx950ui Инструкция по эксплуатации
- APC back-ups bx650li Инструкция по эксплуатации
- APC back-ups bx650li-gr Инструкция по эксплуатации
Скачать
Случайные обсуждения