APC Smart-UPS SURT6000XLI [3/19] Introduction
![APC Smart-UPS SURT6000XLI [3/19] Introduction](/views2/1159314/page3/bg3.png)
Introduction
The APC
by Schneider Electric Smart-UPS
RT is a high-performance, uninterruptible power
supply (UPS) that provides protection for electronic equipment from utility power blackouts,
brownouts, sags and surges. The UPS filters small utility line fluctuations and isolates electronic
equipment from large disturbances by internally disconnecting from utility line power. The UPS
provides continuous power from the internal battery until utility power returns to safe levels or the
battery is fully discharged.
INSTALLATION
Read the Safety Guide before installing the UPS.
Unpacking
Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage.
The packaging is recyclable; save it for reuse or dispose of it properly.
Check the package contents:
UPS (with battery modules disconnected)
Front bezel
Literature kit containing:
Product documentation, Safety Guide,
and Warranty Information
Smart-UPS RT User Manuals CD
Software CD
Serial cable
3000 VA XLI models: two output power cords,
two input power cords
5000/6000 VA XLI models: four output power
cords, Network Management Card
documentation
Specifications
TEMPERATURE
OPERATING
S
TORAGE
32° to 104° F (0° to 40° C)
5° to 113° F (-15° to 45° C) charge the UPS
battery every six months
MAXIMUM
ELEVATION
O
PERATING
S
TORAGE
10,000 ft (3,000 m)
50,000 ft (15,240 m)
This unit is designed for indoor use
only. Select a location sturdy enough to
handle the weight.
Do not operate the UPS where there is
excessive dust or the temperature and
humidity are outside the specified limits.
Ensure that the air vents on the front
and rear of the UPS are not blocked.
HUMIDITY
0 to 95% relative humidity
WEIGHT
UPS
UPS
WITH
PACKAGING
120 lbs (55 kg)
140 lbs (64 kg)
.
1
Содержание
- 5000 6000 va 200 240 vac 1
- English 1
- Smart up 1
- Tower rack mount 3u 1
- Uninterruptible power supply 1
- User manual 1
- By schneider electric smart up 3
- Check the package contents 3
- Four output power cords network management card documentation 3
- Front bezel 3
- Inspect the ups upon receipt notify the carrier and dealer if there is damage 3
- Installation 3
- Introduction 3
- Literature kit containing 3
- Nstallation 3
- Product documentation safety guide and warranty information 3
- Read the safety guide before installing the ups 3
- Rt is a high performance uninterruptible power supply ups that provides protection for electronic equipment from utility power blackouts brownouts sags and surges the ups filters small utility line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from utility line power the ups provides continuous power from the internal battery until utility power returns to safe levels or the battery is fully discharged 3
- Serial cable 3
- Smart ups rt user manuals cd 3
- Software cd 3
- Specifications 3
- The ap 3
- The packaging is recyclable save it for reuse or dispose of it properly 3
- Two output power cords two input power cords 3
- Unpacking 3
- Ups with battery modules disconnected 3
- 6000 va xli models only hardwiring instructions 4
- Wiring and connecting the ups 4
- Connecting the battery modules and attaching the front bezel 5
- Basic connectors 6
- Epo terminal 6
- External battery pack connector 6
- Normal bypass 6
- Output circuitbreaker 6
- Output circuitbreakers 6
- Serial com 6
- Tvss screw 6
- Connecting equipment and power to the ups 7
- Options 7
- Battery charge 8
- Operation 8
- Peration 8
- Smart ups rt front display 8
- On battery operation 9
- Onfigurable 10
- Adhere to national and local electrical codes when wiring the epo 11
- Epo switch 11
- The epo circuit is considered a class 2 circuit ul csa standards and a selv circuit iec standard 11
- The epo switch is internally powered by the ups for use with non powered switch circuit breakers 11
- The output power can be disabled in an emergency by closing a switch connected to the epo 11
- Aintenance and 14
- Ransport 14
- Replacing the battery module 14
- Disconnecting the battery for transport 15
- Arranty 16
- Nformation 16
- Roubleshootin 16
- Use the table below to solve minor installation and operation problems refer to the apc web site www apc com for assistance with complex ups problems 16
- Limited warranty 18
- Service 18
- Apc worldwide customer support 19
- Egulatory 19
- Radio frequency warnings 19
Похожие устройства
- APC Smart-UPS SURT8000XLI Инструкция по эксплуатации
- APC Smart-UPS SUA5000RMI5U Инструкция по эксплуатации
- APC Back-UPS BE700G-RS Инструкция по эксплуатации
- APC Smart-UPS SURT2000XLI Инструкция по эксплуатации
- APC Smart-UPS SC620I Инструкция по эксплуатации
- APC Smart-UPS 10000VA SURT10000XLI Инструкция по эксплуатации
- Aquael easyheater 25w Инструкция по эксплуатации
- Aquael easyheater 50w Инструкция по эксплуатации
- Aquael easyheater 75w Инструкция по эксплуатации
- Aquael easyheater 100w Инструкция по эксплуатации
- Aquael easyheater 150w Инструкция по эксплуатации
- Aquael comfort zone gold 50w Инструкция по эксплуатации
- Aquael comfort zone gold 75w Инструкция по эксплуатации
- Aquael comfort zone gold 100w Инструкция по эксплуатации
- Sony HT-XT100//C Инструкция по эксплуатации
- Sony CDX-G1003ER Инструкция по эксплуатации
- Sony SAL1635Z2 Инструкция по эксплуатации
- Sony STR-DN860//M Инструкция по эксплуатации
- Sony STR-DN1060/M Инструкция по эксплуатации
- Sony MEX-XB100BT Инструкция по эксплуатации
Скачать
Случайные обсуждения