21
4.
TECHNICAL DATA AND RANGE OF USE
 Liquid temperature range:
 KV:
from -15°C to +110°C for the whole range
 Supply voltage:
 50Hz:
1 x 220-240 V
3 x 230-400 V up to 4 KW inclusive
3 x 400 V D over 4 KW
 Flow rate:
from 1.8 to 45 m³/h (see fig. 5-6 page 95-96)
 Head up – Hmax (m):
see fig. 5-6 page 95-96 - page 97
 Degree of motor protection:
IP44 (For IP55 see plate on package)
 Degree of terminal board protection:
IP55
 Thermal class:
F
 Absorbed power
see electric data plate
 Maximum environment temperature:
+40°C
 Storage temperature:
-10°C to +40°C
 Relative humidity of the air:
max. 95%
 Maximum working pressure:
KV 3 - 6 - 10 18 Bar (1800 KPa)
KV 32 - KV 40 25 Bar (2500 KPa)
KV 50 30 Bar (3000 KPa)
 Motor construction: in conformity with standards CEI 2-3 pamphlet 1110
 Weight: see plate on package
 Dimensions: see fig. 1-2, page 93
 Line fuses AM class: indicative values (Amps)
Model Line fuses
1 x 220-240V 50Hz 3 x 230V 50Hz 3 x 400V 50Hz
KV 3/10, KV 3/12, KV 6/7, KV 6/9, KV 10/4 10 8 4
KV 32/34, KV 32/44, KV 32/54, KV 32/64, KV 32/74,
KV 32/84, KV 40/34, KV 40/44, KV 40/54, KV 50/34
- - 8 4
KV 3/15, KV 6/11, KV 10/5 12 10 6
KV 32/94, KV 32/104, KV 32/114, KV 40/64, KV 40/74,
KV 50/44
- - 10 6
KV 10/6 16 10 6
KV 3/18, KV 6/15, KV 10/8, KV 32/2
KV 32/124, KV 32/134, KV 32/144, KV 32/154, KV 40/84,
KV 40/94, KV 40/104, KV 50/54, KV 50/64
- - 12 8
KV 32/3, KV 32/4, KV 40/2,
KV 40/114, KV 40/124, KV 40/134, KV 50/74, KV 50/84,
KV 50/94, KV 50/104, KV 50/114
- - 20 12
KV 32/5, KV 40/3,
KV 50/124, KV 50/134, KV 50/144, KV 50/154
- - 25 16
KV 32/6, KV 32/7, KV 32/8, KV 40/4, KV 40/5
KV 50/2, KV50/3
- - 40 20
KV 40/6, KV 40/7, KV 40/8, KV 50/4, KV 50/5 - - 63 32
KV 50/6 - - 63 40
KV 50/7, KV 50/8 - - 80 50
KV 50/9 - - 125 63
5. MANAGEMENT
5.1
Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with
constant air humidity.
They are supplied in their original packaging and must remain there until the time of installation. If this is
not possible, the intake and delivery aperture must be accurately closed.
5.2
Transport
Avoid subjecting the products to needless jolts or collisions.
To lift and transport the unit, use lifting equipment and the pallet supplied standard (if applicable).
Use suitable hemp or synthetic ropes only if the part can be easily slung, connecting them if possible to the
eyebolts provided. In the case of coupled pumps, the eyebolts provided for lifting one part must not be used
to lift the pump-motor assembly.
5.3
Dimensions and weights
The adhesive label on the package indicates the total weight of the electropump. The dimensions are given
on page 93.