Beko css 54010 gw [15/100] Installation and connection

Содержание

or door available for room ventilation an extra ventilation must be installed The appliance may be located in a kitchen kitchen diner or a bed sitting room but not in a room containing a bath or shower The appliance must not be installed in a bed sitting room of less than 20m3 Do not install this appliance in a room below ground level unless it is open to ground level on at least one side Room size Ventilation opening smaller than 5 m3 5 m3 to 10 m3 greater than 10 m3 den In the cellar or basement mln 100 cm2 mlm 50 cm2 not required mln 65 cm2 Installation and connection Product can only be installed and connected in accordance with the statutory installation rules not install the product next to L 1 Jæfri9erators or freezers The heat emitted h by the product will increase the energy consumption of cooling appliances Carry the product with at least two persons Product must be placed directly on the floor It must not be placed onto a base or a pedestal not use the door and or handle to carry I 1 Jor move the product The door handle or hinges get damaged Electrical connection Connect the product to a grounded outlet line protected by a fuse of suitable capacity as stated in the Technical specifications table Have the grounding installation made by a qualified electrician while using the product with or without a transformer Our company shall not be liable for any damages that will arise due to using the product without a grounding installation in accordance with the local regulations H DANGER The product must be connected to the mains supply only by an authorised and qualified person The product s warranty period starts only after correct installation Manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorised persons H DANGER The power cable must not be clamped bent or trapped or come into contact with hot parts of the product A damaged power cable must be replaced by a qualified electrician Otherwise there is risk of electric shock short circuit or fire The mains supply data must correspond to the data specified on the type label of the product The rating plate is either seen when the door or the lower cover is opened or it is located at the rear wall of the unit depending on the unit type Power cable of your product must comply with the values in Technical specifications table DANGER Before starting any work on the electrical installation disconnect the product from the mains supply There is the risk of electric shock Connecting the power cable 1 If a power cable Is not supplied together with your product a power cable that you would select from the table Technical specifications page 12 in accordance with the electrical installation at your home must be connected to your product by following the instructions in cable diagram If it is not possible to disconnect all poles in the supply power a disconnection unit with at least 3 mm contact clearance fuses line safety switches contactors must be connected and all the poles of this disconnection unit must be adjacent to not above the product in accordance with IEE directives Failure to obey 15 EN

Скачать