Beko cse 62320 gw [16/68] Remove the knob from the gas tap 3 use an appropriately sized screwdriver to

Содержание

J New injectors have their position marked on Jtheir packing or injector table on Injector 1 Stable page 12 can be referred to 1 5 For the last control bring the burner both to high flame and reduced positions and check whether the flame is on or off Depending on the type of gas tap used in your appliance the adjustment screw position may Flame failure device model dependant 2 Spark plug 3 Injector 4 Burner e Unless there is an abnormal condition do j Inot attempt to remove the gas burner taps You must call an Authorised service agent if it is necessary to change the taps Reduced gas flow rate setting for hob taps 1 Ignite the burner that is to be adjusted and turn the knob to the reduced position 2 Remove the knob from the gas tap 3 Use an appropriately sized screwdriver to adjust the flow rate adjustment screw For LPG Butane Propane turn the screw clockwise For the natural gas you should turn the screw counter clockwiseonce The normal length of a straight flame in the reduced position should be 6 7 mm 4 If the flame is higher than the desired position turn the screw clockwise If it is smaller turn anticlockwise 16 EN 1 Flow rate adjustment screw the gas type of the unit is changed then Jthe rating plate that shows the gas type of unit must also be changed 1