Fluke intellitone pro 200 — руководство пользователя по локализации и изоляции кабелей [12/25]

Fluke intellitone pro 200 Инструкция по эксплуатации онлайн [12/25] 153103
IT200
Users Manual
6
To locate and isolate cables, do the following:
1. Connect the IT200 toner to a jack or punch-down
block as shown in Figure 1.
2. Turn the toners rotary switch to
Gfor a one-note
tone or
F for a two-note tone.
3. Turn the IT200 probes rotary switch to
M
(locate).
4. Use the probe to find the general location of the
tone at a cable rack, patch panel, or behind a wall.
The SYNC LED flickers when the probe is receiving
the IntelliTone signal.
In locating mode, the probes LEDs light up from 1 to
8, then wrap back and light up from 1 to 8 again as
the signal strength increases.
Note
If you cannot locate the IntelliTone signal on
2-conductor cables, the cable may be shorted.
Use the cable map test (page 8) to test for shorts
on cables with RJ11 and RJ45 connectors. Use the
continuity test (page 13) to check for shorts on
coax and non-terminated cables.
5. Turn the probes rotary switch to
N (isolate).
6. Use the probe to isolate the tone source in the cable
bundle or at the patch panel. The SYNC LED flickers
when the probe is receiving the IntelliTone signal.
In isolating mode, the probes LEDs light up from 1 to
8 as the signal strength increases.
Note
It is not necessary to touch the IT200 probe tip to
the cabling or patch panel when searching for
the IntelliTone signal.