Fluke intellitone pro 200 — как проверить непрерывность цепей и компонентов с помощью тестера [19/25]

Fluke intellitone pro 200 [19/25] Testing for continuity
Testing for Continuity
13
Testing for Continuity
You can use the toner to test circuits and components for
continuity.
1. If you are testing a circuit, verify that it is not
powered. Use the toners SERVICE function to check
voice and Ethernet circuits for power. Use a voltage
meter to check other types of circuits for power.
2. Turn off the toner.
3. Connect the toner to the circuit or component as
shown in Figure 5.
4. Turn the toners rotary switch to
E.
5. The continuity LED indicates an open or closed circuit
as shown in Figure 5.
>10k
=
=
ash09f.eps
Figure 5. Continuity Test