Zyxel MES3500-10 — ethernet Switch SNMP CLI Commands Guide [267/364]

Превью страниц Страница 267 / 364
Zyxel MES3500-10 [267/364] Snmp server commands
Ethernet Switch CLI Reference Guide
267
CHAPTER 67
SNMP Server Commands
Use these commands to configure SNMP on the Switch.
67.1 Command Summary
The following table describes user-input values available in multiple commands for this
feature.
The following section lists the commands for this feature.
Table 146 snmp-server User-input Values
COMMAND DESCRIPTION
property 1-32 alphanumeric characters
options aaa: authentication, accounting.
interface: linkup, linkdown, autonegotiation, lldp,
transceiver-ddm.
ip: ping, traceroute.
switch: stp, mactable, rmon, cfm.
system: coldstart, warmstart, fanspeed, temperature, voltage,
reset, timesync, intrusionlock, loopguard, poe.
Table 147 snmp-server Command Summary
COMMAND DESCRIPTION M P
show snmp-server Displays SNMP settings. E 3
snmp-server <[contact <system-
contact>] [location <system-
location>]>
Sets the geographic location and the name of the person in
charge of this Switch.
system-contact: 1-32 English keyboard characters;
spaces are allowed.
system-location: 1-32 English keyboard characters;
spaces are allowed.
C13
snmp-server version
<v2c|v3|v3v2c>
Sets the SNMP version to use for communication with the
SNMP manager.
C13
snmp-server get-community
<property>
Sets the get community. Only for SNMPv2c or lower. C 13
snmp-server set-community
<property>
Sets the set community. Only for SNMPv2c or lower. C 13
snmp-server trap-community
<property>
Sets the trap community. Only for SNMPv2c or lower. C 13