Zyxel MES3500-10 [330/364] Chapter 85 additional commands
Chapter 85 Additional Commands
Ethernet Switch CLI Reference Guide
330
This example looks at general system information about the Switch
The following table describes the labels in this screen.
Allocated Power This field displays the total amount of power the Switch has reserved for
PoE after negotiating with the PoE device(s).
Note: If the management mode is set to Consumption, this
field shows NA.
Remaining Power This field displays the amount of power the Switch can still provide for PoE.
Note: The Switch must have at least 16 W of remaining power
in order to supply power to a PoE device, even if the
PoE device requested less than 16 W.
sysname# show system-information
Product Model : MGS-3712
System Name : MGS-3712
System Contact :
System Location :
System up Time : 0:52:47 (4d56b ticks)
Ethernet Address : 00:19:cb:00:00:02
Bootbase Version : V0.5 | 04/02/2008
ZyNOS F/W Version : V3.80(BBA.3)b1 | 04/17/2008
Config Boot Image : 1
Current Boot Image : 1
RomRasSize : 3248840
Table 189 show system-information
LABEL DESCRIPTION
Product Model This field displays the model name.
System Name This field displays the system name (or hostname) of the Switch.
System Contact This field displays the name of the person in charge of this Switch. Use the
snmp-server command to configure this. See Chapter 67 on page 267.
System Location This field displays the geographic location of this Switch. Use the snmp-
server command to configure this. See Chapter 67 on page 267.
System up Time This field displays how long the switch has been running since it last started
up.
Ethernet Address This field displays the MAC address of the Switch.
Bootbase Version This field displays the bootbase version the Switch is running.
ZyNOS F/W Version This field displays the firmware version the Switch is running.
Config Boot Image This field displays which firmware image (1 or 2) is loaded when the Switch
starts up.
Current Boot Image This field displays the firmware image (1 or 2) the Switch is currently using.
RomRasSize This field displays how much ROM is used.
Table 188 show poe-status (continued)
LABEL DESCRIPTION