This example enables the disabled port recovery function and the recovery timer for the
loopguard feature on the Switch. If a port is shut down due to the specified reason, the Switch
activates the port 300 seconds (the default value) later. This example also shows the number of
the disabled port(s) and the time left before the port(s) becomes active.
sysname# configure
sysname(config)# errdisable recovery
sysname(config)# errdisable recovery cause loopguard
sysname(config)# exit
sysname# show errdisable recovery
Errdisable Recovery Status:Enable
Reason Timer Status Time
---------- ------------ -------
loopguard Enable 300
ARP Disable 300
BPDU Disable 300
IGMP Disable 300
Interfaces that will be enabled at the next timeout:
Interface Reason Time left(sec) Mode
--------- ---------- -------------- ---------------
sysname#