CONEL SPECTRE v3 ERT — технические параметры и испытания для оборудования [33/39]

Превью страниц Страница 33 / 39
CONEL SPECTRE v3 ERT [33/39] Type tests and environmental conditions
7. TECHNICAL PARAMETERS
7.2 Type tests and environmental conditions
Phenomena Test Description Test levels
ESD EN 61000-4-2 Enclosure contact
Enclosure air
± 6 kV (crit. A)
± 8 kV (crit. A)
RF field AM
modulated
IEC 61000-4-3 Enclosure 20 V/m (crit. A)
(80 2700 MHz)
Fast transient EN 61000-4-4 Signal ports
Power ports
Ethernet ports
± 2 kV (crit. A)
± 2 kV (crit. A)
± 2 kV (crit. A)
Surge EN 61000-4-5 Ethernet ports
Power ports
I/O ports
± 2 kV (crit. B), shielded
cabel
± 0,5 kV (crit. B)
± 1 kV, L to L (crit. A)
± 2 kV, L to GND (crit. A)
RF conducted EN 61000-4-6 All ports 10 V/m (crit. A)
(0,15 80 MHz)
Radiated emission EN 55022 Enclosure Class B
Conducted
emission
EN 55022 DC power ports
Ethernet ports
Class B
Class B
Power frequency
magnetic field
EN 61000-4-8 Enclosure 160 A/m (crit. A)
Dry heat EN 60068-2-2 +75
C
1
, 40 % rel. humidity
Cold EN 60068-2-1 -40
C
1
EMC/Immunity
for industrial
environments
ˇ
CSN
EN 61000-6-2
ed.3
Generic standards Frequency range 0 Hz to
400 GHz are covered
Table 22: Type tests and environmental conditions
1
The temperatures are given for basic version of the router. For example, if the router is equipped with WiFi
module, values are slightly worse.
26

Содержание

93

Изучите технические параметры и условия испытаний для оборудования, включая электромагнитную совместимость и устойчивость к внешним воздействиям.

Кешбек Менеджер