Yealink SIP-T48G [114/384] Descriptions web setting path

Yealink SIP-T48G [114/384] Descriptions web setting path
Yealink IP Phones Auto Provisioning Guide
108
Parameter
Permitted
Values
Descriptions
Web Setting Path
phone_setting.vq_rtcpxr_interval_period
Integer from 5
to 20
It configures the interval (in seconds) for the IP
phone to send an interval quality report to the
central report collector periodically
throughout a call.
The default value is 20.
Settings->Voice Monitoring->Period
for Interval Report
phone_setting.vq_rtcpxr_moslq_threshold_warning
15 to 40
It configures the threshold value of listening
MOS score (MOS-LQ) multiplied by 10. The
threshold value of MOS-LQ causes the phone
to send a warning alert quality report to the
central report collector.
For example, a configured value of 35
corresponds to the MOS score 3.5. When the
MOS-LQ value computed by the phone is less
than or equal to 3.5, the phone will send a
warning alert quality report to the central
report collector. When the MOS-LQ value
computed by the phone is greater than 3.5,
the phone will not send a warning alert
quality report to the central report collector.
If it is set to blank, warning alerts are not
generated due to MOS-LQ.
The default value is blank.
Settings->Voice Monitoring->Warning
threshold for Moslq