Graco Python 5/8" [55/56] Python chemical injection pump

Graco Python 3/4
Technical Data
3A3101D 55
Technical Data
Python Chemical Injection Pump
US Metric
Maximum air inlet pressure See Models on page 3.
Maximum fluid working pressure See Models on page 3.
Environmental temperature range -40°–176°F -40°–80°C
Noise (dBa)
Maximum sound pressure
<70 dBa with included muffler installed.
Inlet/Outlet Sizes
Fluid inlet size 1/4 in. npt(f) (1/4 npt(m) adapter included)
Fluid outlet size (1/4”, 3/8”, 1/2”, 5/8”, & 3/4”
plungers only)
1/4 in. npt(f)
Fluid outlet size (1/8” & 3/16” plungers only) HiP HF4
Prime/bleed size (1/4”, 3/8”, 1/2”, 5/8”, & 3/4”
plungers only)
10-32 UNF
Prime/bleed size (1/8” & 3/16” plungers only) 1/16 in. npt(f)
Pneumatic inlet size 1/8 in. npt(f) (1/4 npt(f) adapter included)
Pneumatic outlet size (exhaust recovery) 1/8 in. npt(f)
Materials of Construction
Pump/Check Valve Seal Material
See Configuration Chart on page 4 for seal material. All
other packing materials are PEEK and PTFE unless other-
wise noted.
Wetted Parts
See Configuration Chart on page 4 for plunger material. All
other materials are 316 stainless steel unless otherwise
noted.
Weight
All models 8-11 lbs. 3.6-4.9 kg

Содержание