Graco Therm-O-Flow 200 Инструкция по эксплуатации онлайн [32/109] 168113

Graco Therm-O-Flow 200 Инструкция по эксплуатации онлайн [32/109] 168113
Operation
7.Ifanewdrumwasinstalledandtheunitis
equippedwithproximitysensors,pressthePump
Readybutton .Presspausebutton on
materialtracking.
8.Adjusttheairmotorairregulator(CK)upby5psi
(34kPa,0.3bar).Neveradjusttheregulatorby
morethan5psi(34kPa,0.3bar)increments.
Makesurethepumpbeginstocycleandheated
materialowsfromthebleedstem(Z)after
severalcyclesofthepump.
9.Primethepumpuntilitmovessmoothlyin
bothdirectionswithnoairpoppingorerratic
movementandclosethemainairslidervalve
(CA).
10.Closethebleedstem(Z).
11.PressPlaybutton onhomescreentoenable
materialtracking.
32334130D