Graco Therm-O-Flow 200 [57/109] Update software

Graco Therm-O-Flow 200 [57/109] Update software
Repair
Update Update
Update
Software Software
Software
WhensoftwareisupdatedontheADMthesoftware
isthenautomaticallyupdatedonallconnected
GCAcomponents.Astatusscreenisshownwhile
softwareisupdatingtoindicateprogress.
1.TurnsystemmainpowerswitchOFF.
2.RemoveADMfrombracket.
3.Removetokenaccesspanel.
4.Insertandpresssoftwareupgradetoken(T)
rmlyintoslot.
Note
Thereisnopreferredorientationoftoken
T
5.InstallADMintobracket.
6.TurnsystemmainpowerswitchON.
NOTICE NOTICE
NOTICE
Astatusisshownwhilesoftwareisupdatingto
indicateprogress.Topreventcorruptingthe
softwareload,donotremovetokenuntilthe
statusscreendisappears.
Note
Whenthescreenturnson,youwillsee
thefollowingscreens:
First: First:
First:
Softwareischecking
whichGCAmodules
willtaketheavailable
updates.
Second: Second:
Second:
Statusoftheupdate
withapproximatetime
untilcompletion.
Third: Third:
Third:
Updatesare
complete.Icon
indicatesupdate
success/failure.See
thefollowingIcon
table.
Icon Icon
Icon
Description Description
Description
Updatesuccessful.
Updateunsuccessful.
Updatecomplete,no
changesnecessary.
Updatewas
successful/complete
butoneormoreHCA
modulesdidnothave
aCANboot-loader
sosoftwarewas
notupdatedonthat
module.
334130D57

Содержание