Moxa EDS-G512E-4GSFP-T [31/116] Port event settings

Moxa EDS-518E-4GTXSFP-T [31/116] Port event settings
Managed Ethernet Switch (UI_2.0_FW_5.x) Featured Functions
3-18
Port Event Settings
Port Events are related to the activity of a specific port.
Port Events Warning e-mail is sent when…
Link-ON The port is connected to another device.
Link-OFF The port is disconnected (e.g., the cable is pulled out, or the opposing
device shuts down).
Traffic-Overload The port’s traffic surpasses the Traffic-Threshold for that port (provided
this item is Enabled).
Traffic-Threshold (%) Enter a nonzero number if the port’s Traffic-Overload item is Enabled.
Traffic-Duration (sec.) A Traffic-Overload warning is sent every Traffic-Duration seconds if the
average Traffic-Threshold is surpassed during that time period.
Four response actions are available on the EDS E series when events are triggered.
Action Description
Trap The EDS E series will send a notification to the trap server when an event is triggered.
E-Mail The EDS E series will send a notification to the email server defined in the Email Setting.
Syslog The EDS E series will record a syslog to syslog server defined in Syslog Server Setting.
Relay The EDS E series supports digital inputs to integrate sensors. When an event is triggered,
the device will automate alarms through the relay output.
Severity
Severity Description
Emergency System is unusable
Alert Action must be taken immediately
Critical Critical conditions
Error Error conditions
Warning Warning conditions
Notice Normal but significant condition
Information Informational messages
Debug Debug-level messages
NOTE
The Traffic
-Overload, Traffic-Threshold (%), and Traffic-
Duration (sec.) Port Event items are related. If you
Enable
the Traffic-Overload event, then be sure to enter a nonzero Traffic-
Threshold percentage, as well as a
Traffic
-Duration between 1 and 300 seconds.