Moxa ICS-G7852-4XG-HV-HV [2/2] Rack mounting instructions
![Moxa ICS-G7848-HV-HV [2/2] Rack mounting instructions](/views2/1197115/page2/bg2.png)
– 5 – – 6 – – 7 – - 8 -
www.moxa.com/support
The Americas:
+1-714-528-6777 (toll-free: 1-888-669-2872)
Europe:
+49-89-3 70 03 99-0
Asia-Pacific:
+886-2-8919-1230
China:
+86-21-5258-9955 (toll-free: 800-820-5036)
2010 Moxa Inc. All rights reserved.
LEDs
LED
Color
State
Description
System LEDs
STATE
GREEN
On
The system passed the self-diagnosis
test on boot-up and is ready to run.
Blinking
The system is undergoing the
self-diagnosis test.
RED On
The system failed self-diagnosis on
boot-up.
PWR1 AMBER
On
Power is being supplied to the main
module’s power input PWR1.
Off
Power is not being supplied to the main
module’s power input PWR1.
PWR2 AMBER
On
Power is being supplied to the main
module’s power input PWR2.
Off
Power is not being supplied to the main
module’s power input PWR2.
FAULT RED
On
The system has failed, or is under quick
inspection.
Off The system is operating normally.
MSTR/
HEAD
GREEN
On
The switch is set as the Master of the
Turbo Ring, or as the Head of the Turbo
Chain.
Blinking
The switch
has become the Ring Master
of the Turbo Ring, or the Head of the
Turbo Chain, after the Turbo Ring or the
Turbo Chain is down.
Off
The switch is not the Master of this Turbo
Ring or is set as a
Member of the Turbo
Chain
CPLR/
TAIL
GREEN
On
The switch’s coupling function is enabled
to form a back-
up path, or when it’s set
as the Tail of the Turbo Chain.
Blinking
Turbo Chain is down
Off
This switch has disabled the coupling
function.
LED Color State Description
Mail Module LED Status
10 GbE
(Fiber Optic
Port)
GREEN On The corresponding port’s link is
active.
Blinking
Data is being transmitted.
Off The corresponding port’s link is
inactive.
LED
Color
State
Description
IM-G7000 Module LED Status
IM-G7000-
4GTX 10/
100/1000
Mbps (TP
Ports)
GREEN On The corresponding port's link is
active at 1000 MBps
Blinking Data is being transmitted at 1000
Mbps.
Off The corresponding port’s link is
inactive.
AMBER On The corresponding port's link is
active at 10/100 MBps
Blinking
Data is being transmitted.
Off The corresponding port’s link is
inactive.
IM-G700-
4GSFP 100/
1000 MBPS
(Fiber Optic
Ports)
GREEN
On
The corresponding port's link is
active at 1000 MBps
Blinking
Data is being transmitted.
Off The corresponding port’s link is
inactive.
AMBER On The corresponding port's link is
active at 100 MBps
Blinking
Data is being transmitted.
Off The corresponding port’s link is
inactive.
HOT SWAP
STATE
Green
On
The module is working
Blinking The module is uninstalling
Off The module is not working or is
safe to be removed
Specifications
Technology
Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
IEEE 802.3ae for 10 Gigabit Ethernet
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
MIB MIB-II, Ethernet-like MIB, P-BRIDGE MIB,
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON
MIB Groups 1, 2, 3, 9
Interface
Gigabit Ethernet
10/100/1000BaseT(X) or 100/1000BaseSFP slot
10 Gigabit
Ethernet
10GbE SFP+ slot
Console Port RS-232 (RJ45 connector)
LED Indicators STATE, PWR1, PWR2, FAULT, MSTR/HEAD,
CPLR/TAIL
Alarm Contact
1 relay output with current carrying capacity of 2
A @ 30 VDC
Digital Inputs 1 input with the same ground, but electrically
isolated from the electronics.
• +13 to +30V for state “1”
• -30 to +3V for state “0”
• Max.input current: 8 mA
Power Requirements
Input Voltage 110/220 VAC (85 to 264 VAC)
Input Current ICS-G7748/7848:
Max. 1.02/0.46 A @ 110/220 VAC
ICS-G7750/7850:
Max. 1.10/0.49 A @ 110/220 VAC
ICS-G7752/7852:
Max. 1.19/0.52 A @ 110/220 VAC
Overload Current
Protection
Present
Physical Characteristics
Housing IP 30 protection
Dimensions 440 x 176 x 482.8 mm
Installation 4U 19” rack mounting
Environmental Limits
Operating Temp. 0 to 60°C (32 to 140°F)
Storage Temp. -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity.
5 to 95% (non-condensing)
Standards and Certifications
Safety
UL 60950-1, EN 60950-1
EMI
FCC Part 15 Subpart B Class A, EN 55022 Class A
Rail Traffic
EN50121-4
Warranty
Warranty Period
5 years
Details
See www.moxa.com/warranty
Rack Mounting Instructions
1. Elevated Operating Ambient: If installed in a closed or
multi-unit rack assembly, the operating ambient temperature of
the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
2. Reduced Air Flow: Installation of the equipment in a rack
should be such that the amount of air flow
required for safe operation of the equipment is
not compromised.
3. Mechanical Loading: Mounting of the
equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical
loading.
4. Circuit Overloading: Consideration should be given to the
connection of the equipment to the supply circuit and the effect
that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing
this concern.
5. Reliable Earthing: Reliable earthing of rack-mounted
equipment should be maintained. Particular attention should be
given to supply connections other than direct connections to the
branch circuit (e.g. use of power strips)."
Restricted Access Locations
• This equipment is intended to be used in Restricted Access
Locations, such as a computer room, with access limited to
SERVICE PERSONAL or USERS who have been instructed on how
to handle the metal chassis of equipment that is so hot that
special protection may be needed before touching it. The
location should only be accessible with a key or through a
security identity system.
External metal parts of this equipment are extremely hot!! Before
touching the equipment, you must take special precautions to
protect your hands and body from serious injury.
Содержание
- Connecting the power inputs 1
- Dimensions unit mm 1
- Front view 1
- G7850 g7852 series 1
- Grounding the industrial rackmount switch 1
- Hardware installation guide 1
- Ics g7748 g7750 g7752 g7848 1
- Installing removing ics switch modules 1
- Package checklist 1
- Panel layouts 1
- Rear view 1
- Second edition september 2011 1
- Rack mounting instructions 2
- Restricted access locations 2
- Specifications 2
Похожие устройства
- Moxa ICS-G7852-4XG-HV-HV Руководство по созданию резервированных сетей
- Moxa ICS-G7852-4XG-HV-HV Руководство по использованию командной строки
- Moxa ICS-G7852-4XG-HV-HV Технические характеристики
- Moxa IM-G7000-4GTX Инструкция по эксплуатации
- Moxa IM-G7000-4GSFP Инструкция по эксплуатации
- Moxa IM-G7000A-4PoE Инструкция по эксплуатации
- Moxa IM-G7000A-4GTX Инструкция по эксплуатации
- Moxa IM-G7000A-4GSFP Инструкция по эксплуатации
- Moxa EDS-608 Инструкция по эксплуатации
- Moxa EDS-608 Руководство пользователя Англ.
- Moxa EDS-608 Руководство по аппаратной части
- Moxa EDS-608 Технические характеристики
- Moxa EDS-608-T Инструкция по эксплуатации
- Moxa EDS-608-T Руководство пользователя Англ.
- Moxa EDS-608-T Руководство по аппаратной части
- Moxa EDS-608-T Технические характеристики
- Moxa EDS-611 Инструкция по эксплуатации
- Moxa EDS-611 Руководство пользователя Англ.
- Moxa EDS-611 Руководство по аппаратной части
- Moxa EDS-611 Технические характеристики