Moxa CP-132UL-T [2/2] Ordering information

Moxa CP-132UL-DB9M [2/2] Ordering information
Multiport Serial Boards
2
© Moxa Inc. All rights reserved. Updated Apr. 15, 2016. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.
CP-132UL-ICP-132UL
CBL-M25M9x2-50
DB25 male to DB9 male x 2
(50 cm cable)
PIN RS-422 RS-485-4w RS-485-2w
1 TxD-(A) TxD-(A)
2 TxD+(B) TxD+(B)
3 RxD+(B) RxD+(B) Data+(B)
4 RxD-(A) RxD-(A) Data-(A)
5 GND GND GND
6 RTS-(A)
7 RTS+(B)
8 CTS+(B)
9 CTS-(A)
DB9 male
Ordering Information
Available Models
CP-132UL-DB9M: 2-port RS-422/485 low profile Universal PCI serial board, 0 to 55°C operating
temperature (CBL-M25M9x2-50 cable included)
CP-132UL-I-DB9M: 2-port RS-422/485 low profile Universal PCI serial board with electrical isolation, 0 to
55°C operating temperature (CBL-M25M9x2-50 cable included)
CP-132UL-T: 2-port RS-422/485 low profile Universal PCI serial board, -40°C to 85 operating temperature
CP-132UL-I-T: 2-port RS-422/485 low profile Universal PCI serial board with electrical isolation, -40°C to
85 operating temperature
Connection Options (can be purchased separately)
Low Profile Bracket: Bracket for DB44 connector (3095010000007)
CBL-M25M9x2-50: M25 to 2 x DB9-M cable, 50 cm
Package Checklist
• 1 CP-132UL or CP-132UL-I board
• Low profile bracket
• 1 connection cable (optional)
• Documentation and software CD
• Quick installation guide (printed)
• Warranty card
RS-485-4w: TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND
RS-485-2w: Data+(B), Data-(A), GND
Physical Characteristics
Dimensions:
CP-132UL: 64.4 x 120 mm (2.53 x 4.72 in)
CP-132UL-I: 64.4 x 120 mm (2.53 x 4.72 in)
Driver Support
Windows: Windows 95/98/ME/NT/2000, Windows XP/2003/
Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2
(x64), DOS, Windows Embedded CE 5.0/6.0, Windows XP Embedded
Linux: Linux 2.4.x, 2.6.x, 3.x
Unix-like Systems: QNX 6, SCO OpenServer, UnixWare 7, Solaris 10,
FreeBSD
Note: Please refer to Moxa’s website for the latest driver support information.
Environmental Limits
Operating Temperature:
Standard Models: 0 to 55°C (32 to 131°F)
Wide Temp. Models: -40 to 85°C (-40 to 185°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
EMC: EN 55022/24
EMI: CISPR 22, FCC Part 15B Class B
EMS:
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
MTBF (mean time between failures)
Time: 1,647,832 hrs
Standard: Telcordia (Bellcore) TR/SR
Power Requirements
Input Current:
CP-132UL: 120 mA @ 5 VDC
CP-132UL-I: 490 mA @ 5 VDC
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Dimensions
Unit: mm (inch)
1
5
6 9
JP1
JP2
120 (4.72)
64.4 (2.53)
80.35 (3.16)
121 (4.76)
41.7 (1.64)
16 (0.63)
JP1
JP2
120 (4.72)
64.4 (2.53)
80.35 (3.16)
121 (4.76)
41.7 (1.64)
16 (0.63)

Похожие устройства