UC-8410A Series Linux Software Advanced Configuration of Peripherals
3-10
Diagnosing Device and Subsystem Failures
The red LED will start blinking once you press the push button. Keep the button pressed until the green LED is
lit for the first time and then release the button to enter diagnostic mode to check which peripherals are
available on the UC-8410A-LX. When diagnostic program is running, the red LED will be blinking.
Status Red LED Yellow LED Green LED
Execution of diagnostic program Blinking Off On
The following two tables describe the diagnostic results related to hardware defects and system operation.
Hardware Defects
If you observe any of these hardware issues, contact Moxa for further instructions.
Priority Status Description Green LED Yellow LED Red LED
1 Proceeding with
self-diagnosis
On Off Blinking
2 LAN1 Ethernet Error
LAN1
Ethernet controller
malfunction
Off Off On
3 LAN2 Ethernet Error
LAN2
Ethernet controller
malfunction
Blinking Off On
4 LAN3 Ethernet Error
LAN3
Ethernet controller
malfunction
On Off On
5 UART Interface Error Any
one of UART interfaces is
malfunctioning
Off On On
6 LED device issue Blinking Blinking Blinking
7 Button device issue Off Blinking On
8 Ready for reset to factory
default
On Blinking Blinking
9 CPU usage (over 90%) Off On Blinking
10 RAM usage (over 90%) Off On Off
11 Disk usage (over 90%) Blinking On Off
12 File system corrupted Blinking On Blinking