Moxa V2426-W7E [20/48] Connecting data transmission cables

Moxa V2406-24I-CT-T-LX [20/48] Connecting data transmission cables
V2406/2422/2426 Hardware Manual Hardware Connection Description
3-5
Connecting Data Transmission Cables
This section describes how to connect the V2406/2422/2426 embedded computers to the network and serial
devices.
Connecting to the Network
V2406/2426
Plug yo
ur network cable into the embedded computer’s
Ethernet port. The other end of the cable should be plugged
into your Ethernet network. When the cable is properly
connected, the LEDs on the embedded computer’s Ethernet
port will glow to indicate a valid conn
ection.
Two 10/100 Mbps Ethernet ports using M12 connectors are
located on the front panel. See the figure at the right for pin
assignments.
V2422
Two 10/100/1000 Mbps Ethernet ports using RJ45
connectors are located on the front panel. See the table at
the right for
pin assignments.
PIN 10/100 Mbps 10/100/1000 Mbps
1 ETx+ TRD(0)+
2 ETx- TRD(0)-
3 ERx+ TRD(1)+
4 TRD(2)+
5 TRD(2)-
6 ERx- TRD(1)-
7 TRD(3)-
8 TRD(3)+
Connecting to a Serial Device
Use a serial cable to plug your serial device into the embedded computer’s serial port. Serial ports P1 to P4 have
male DB9 connectors and can be configured for RS-232, RS-422, or RS-485 communication by software. The
pin assignments are shown in the following table:
DB9 Male Port RS-232/422/485 Pinouts
Pin RS-232 RS-422 RS-485-4W RS-485-2W
1 DCD TxDA(-) TxDA(-)
2 RxD TxDB(+) TxDB(+)
3 TxD RxDB(+) RxDB(+) DataB(+)
4 DTR RxDA(-) RxDA(-) DataA(-)
5 GND GND GND GND
6
DSR
7 RTS
8 CTS