Moxa OnCell 5104-HSPA [42/67] Firmware upgrade

Moxa OnCell 5104-HSPA [42/67] Firmware upgrade
OnCell 5000 Series System Management Settings
5-7
Group Event
System System Cold Start, System Warm Start, Power 1 DOWN, Power 2 DOWN, Cell.
module awake/fail, Cell. module close/over temperature range
Network DHCP/BOOTP Get IP/Renew, NTP, Mail Fail, NTP Connect Fail, IP Conflict, Network
Link Down, Cell. module get/lost IP
Config Login Fail, IP Changed, Password Changed, Config Changed, Firmware Upgrade,
SSL Key Import, Config Import, Config Export
Input Din 1 turn on, Din 1 turn off, Din 2 turn on, Din 2 turn off
Firmware Upgrade
The OnCell 5000’s firmware can be upgraded though the web console or the OnCell Search Utility. If you have
made any changes to your configuration, remember to save the configuration first before upgrading the
firmware. Please refer to Save Configuration later in this chapter for more information. Any unsaved changes
will be discarded when the firmware is upgraded. To upgrade the firmware, simply enter the file name and click
Submit. The latest firmware can be downloaded from www.moxa.com
.
Configuration Import/Export
The OnCell 5000 can share or back up its configuration by exporting all settings to a file.
To import a configuration, go to System Management
Maintenance
Configuration Import. Enter the
configuration file path/name and click Submit. The OnCell 5000’s configuration settings will be updated
according to the configuration file. If you also wish to import the IP configuration (i.e., the OnCell 5000’s IP
address, netmask, gateway, etc.), make sure that Import all configurations including IP configurations
is checked.
To export a configuration, go to System Management
Maintenance
Configuration Export and click
Download. A standard download window will appear to allow you to download the configuration into a file and
location of your choice.