Moxa VPort P26A-1MP [24/82] Wiring requirements

Moxa VPort 26A-1MP-T [24/82] Wiring requirements
Moxa VPort 26A-1MP Getting Started
2-10
Wiring Requirements
ATTENTION
Be sure to disconnect the power cord before installing and/or wiring your M
oxa VPort 26A-1MP.
Calculate the maximum possible current in each power wire and common wire. Observe all el
ectrical codes
dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your
equipment.
You should also pay attention to the following:
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must
cross make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid
interference, wires with different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to determine which wires should be kept separate.
The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
Keep input wiring and output wiring separate.
It is strongly advised that you label wiring to all devices in the system when necessary.
WARNING
This equipm
ent is intended to be used in a Restricted Access Location.