Moxa VPort P06-1MP-M12-CAM42-T [41/83] Modbus tcp not supported by all vports

Moxa VPort 36-1MP-IVA-T [41/83] Modbus tcp not supported by all vports
VPort ONVIF Profile S System Configuration
4-24
Trap Settings
Setting Description Default
Trap Server
IP/Name
Enter the IP address or name of the Trap
Server used by your
network.
No
Trap Community
Use a community string match for authentication; Maximum of
30 characters.
No
General item
There are 4 items that can be configured to send the trap by the user: Cold Start, Configuration Changed, New
IP, Record Status Changed
Private MIB information
Different VPorts have different object IDs.
NOTE
The MIB f
ile is MOXA-VPORTXX-
MIB.mib (or.my). You can find it on the software CD or the download center of
the Moxa website.
Modbus/TCP (not supported by all VPorts)
Modbus is a serial communications protocol that is often used to connect a supervisory computer with a remote
terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems. To transmit Modbus over a
TCP/IP network, a standard Modbus/TCP protocol is provided. With the support of the Modbus/TCP protocol,
the SCADA/HMI system can directly communicate with the VPort to acquire its operational status.
Setting Description Factory Default
Enable Modbus/TCP Enable the Modbus/TCP protocol Disable
NOTE
For
the Modbus address table, refer to Modbus_Address_Define.pdf. You can find it on your VPort’s
software CD
or
in download center on the Moxa website.
MoxaCmd/Moxa Service (not supported by all VPorts)
MoxaCmd is a Moxa proprietary discovery method. In some cases, users can disable MoxaCmd to prevent the
camera from being discovered by Moxa’s VPort and EtherDevice Configurator Utility.