Moxa VPort P06-1MP-M12-CAM60 [52/65] Vport p06 1mp m12 system configuration

Moxa VPort P06-1MP-M12-CAM60 [52/65] Vport p06 1mp m12 system configuration
VPort P06-1MP-M12 System Configuration
4-30
Setting Description Factory Default
Enable To enable or disable the DynaStream function. Disable
Duration
Refers to the time period that DynaStream is in operation. For
example, if the duration is set to 5 seconds, then the frame rate
will change from Live to the Alarm status, and remain in Alarm
status for a duration of 5 seconds. After 5 seconds, the frame
rate will return to the Live status setting.
5 seconds
Trigger Channel To enable or disable the video channels. Disabled
Alarm
Basic
On this page you can configure some general parameters of the VPort P06-1MP-M12’s alarm function, including
alarm time interval, alarm snapshot, and suffix of image file name.
Alarm Time Interval
Setting Description Default
Number of delay
second(s) before
detecting the next
alarm
Set the minimum time interval before another event alarm is
triggered.
32 seconds
(10 to 999 seconds)
NOTE
The delay before triggering the next alarm cannot be less than the time needed to take a snapshot after an
event (post
-event image).
Send Alarm with Snapshot images
Setting Description Default
Take a snapshot this
number of seconds(s)
before the event
A snapshot image is taken this number of seconds before the
event alarm is triggered.
2 seconds
(from 1 to 6
seconds)
Take a snapshot this
number of seconds(s)
after the event
A snapshot image is taken this number of seconds after the
event alarm is triggered.
11 seconds
(from 1 to 999
seconds)
NOTE
VPort products will take 3 JPEG snapshot images: VPRE.JPG (pre
-
event), VTRG.JPG (the moment of the event)
and VPOS.JPG (post
-event) for the video channel when the trigger condition is met.
The three snapshots can
also be downloaded by Email and FTP.