Moxa VPort 364A-S-SC [73/88] Digital inputs

Moxa VPort 364A [73/88] Digital inputs
VPort 364A System Configuration
5-37
Trigger Conditions and Actions
Administrators can set triggers, such as Trigger Relay1 alarm, Trigger Relay2 alarm, Send snapshot image via
E-mail, Send snapshot image via FTP, and Send Message via HTTP Event servers for each VMD.
Setting Description Default
Trigger Relay1 alarm Once this DI is triggered, the Relay1 alarm will be activated Disabled
Trigger Relay2 alarm Once this DI is triggered, the Relay2 alarm will be activated Disabled
Send snapshot image
via E-mail
Once this VMD is triggered, the VPort will send the snapshot
images set in the Event Alarm/Basic page to the E-mail
addresses, which are set in the Network/ SMTP Server page.
Disabled
Send snapshot image
via FTP
Once this VMD is triggered, the VPort will send the snapshot
images set in the Event Alarm/Basic page to the FTP server,
which are set in the Network/ FTP Server page.
Disabled
Send message via HTTP
Event Servers
Once this VMD is triggered, the VPort will send the message set
in HTTP Action Setting to the HTTP event servers, which
are set
in the Network/ HTTP Event Server page.
Disabled
HTTP Action Setting
Setting Description Default
Server 1, 2, 3, or 4 Select the HTTP event server for sending the HTTP action Disabled
Blank text box For customizing the message to the HTTP event server. Blank
Digital Inputs
Four digital inputs are provided by the VPort for linking with alarm detection devices, such as sensors.