Zanussi FA 1023 16серв-инстр zanussi fa1023 225EN таймер, плата, схемы, циклы англ стр17 онлайн [7/17] 51343

SAFETY FEATURES
ANTI-UNBALANCING DURING SPINNING
Control of the balance of the load is performed while the drum rotates at a speed of 85 rpm, i.e. before the
spin cycle. If the load is particularly unbalanced, the drum rotates three times at a speed of 55 rpm; at the
end the load condition is checked again.
If the load remains unbalanced, this procedure is repeated once again; the series of attempts to balance the
load is limited to the max. time of every spin phase (382 or 480 sec.). After this period, the timer passes to
the next step, and the spin cycle is skipped.
DRUM MOTOR PROTECTION SYSTEM
In case of the following faults:
- tachometric generator open
- tachometric generator short-circuited
- triac which powers the motor open
- triac which powers the motor short-circuited
- rotor blocked
- motor overload cut-out open or motor windings broken
the electronic PCB makes three attempts to supply power to the motor; if the malfunction is still present
three further attempts are performed after a pause of 20 minutes; no power is supplied to the motor (relay
contacts open).
During these attempts the drum reaches a rotation speed of about 260 rpm.
DRAIN PROTECTION SYSTEM
If during the drain phase the contacts of the pressure switch do not close in the "empty" position after three
minutes (drain pump faulty), the timer advances to the next position.