Hama ews-180 [2/19] D operating instruction
Содержание
- Electronic weather station ews 180 1
- Elektronische wetterstation 1
- D operating instruction 2
- Bedienungsanleitung 5
- Q hliri 6
- Еи руководство по эксплуатации 8
- Istruzioni per i uso 11
- Q fnffi 12
- Instrukcja obslugi 14
- Qi fîim 15
- Wskazówka ustawianie zegara 15
- Ез ръководство за обслужване 17
- Q яш 18
- О яш 18
- Указание времева зона 18
Похожие устройства
- Hama ews-200 Инструкция по эксплуатации
- Hama ews-280 Инструкция по эксплуатации
- Hama ews-800 Инструкция по эксплуатации
- Hama ews-810 Инструкция по эксплуатации
- Hama ews-860 Инструкция по эксплуатации
- Hama ews-880 h-113985 Инструкция по эксплуатации
- Hama ews-890 h-113986 Инструкция по эксплуатации
- Hama th-200 Инструкция по эксплуатации
- Hama т-350 h-123143 Инструкция по эксплуатации
- Hama eco 3000 Инструкция по эксплуатации
- Hama eco 1500 Инструкция по эксплуатации
- Hama eco 1000 Инструкция по эксплуатации
- Hama eco 600 Инструкция по эксплуатации
- Hama electronic 2.5 Инструкция по эксплуатации
- Hama electronic 1.0 Инструкция по эксплуатации
- Hammer plr900, 800 вт Инструкция по эксплуатации
- Hammer SPL150 Инструкция по эксплуатации
- Hammer plr450 Инструкция по эксплуатации
- Hammer tsl350b Инструкция по эксплуатации
- Hammer tsl350c Инструкция по эксплуатации
d Operating instruction 5 Installation Controls and Displays 1 Measuring station radio symbol 2 Outdoor temperature 3 Room temperature 4 Time This symbol is used to indicate additional information or Immediately remove and dispose of dead batteries from important notes the product 5 Day 6 Radio symbol Only use batteries or rechargeable batteries that match 2 Package Contents the specified type EWS 180 weather station Do not mix old and new batteries or batteries of a different 7 Time zone 8 Day of the week seconds 9 Month 10 Alarm symbol 11 ALARM button display set alarm modes 12 MODE button settings confirm the setting value toggle among seconds day of the week and time zone displays 13 A button increase the current setting activate or deactivate manual radio signal reception 14 C F button switch between C and F 15 MEM button access reset the stored maximum minimum values 16 button reduce the current set value manually search for a signal from the measuring station 17 Opening for wall mounting 18 Battery compartment 19 Base base station for indoors measuring station for outdoors type or make 2 AAA batteries When inserting batteries note the correct polarity and 2 AA batteries markings and insert the batteries accordingly Failure to do These operating instructions so could result in the batteries leaking or exploding We recommend initially placing the base and measuring stations in the intended locations without installing them and making all the settings described in 6 Operation to do Only install the stations once the appropriate settings have been made and a stable wireless connection is established Do not overcharge batteries 3 Safety Notes The product is intended for private non commercial use only Do not use the product in moist environments and avoid Keep batteries out of the reach of children Do not short circuit the batteries rechargeable batteries and keep them away from uncoated metal objects Do not use the product in the immediate vicinity of heaters or 4 Getting Started Before installation ensure that wireless transmission will 4 1 Inserting the batteries trees vehicles high voltage lines etc not be disrupted by interference or obstacles like buildings other heat sources or in direct sunlight Do not use the product in areas where the use of electronic Before the final installation ensure that there is sufficient devices is not permitted Do not place the product near interference fields metal frames computers TVs etc Electronic devices and window frames can negatively affect the product s functionality Measuring station Open the battery compartment 22 and remove the contact breaker Replace the battery compartment cover Do not drop the product and do not expose it to any major shocks Do not open the device or continue to operate it if it becomes damaged The wireless transmission range between the measuring and base stations is up to 30 m in open spaces splashes Base station reception between the intended installation locations When installing the measuring station ensure that it is protected from direct sunlight and rain The international standard height for measuring air temperature is 1 25 m 4 ft above ground Open the battery compartment 18 and remove the contact breaker Replace the battery compartment cover Do not attempt to service or repair the product yourself Leave B Measuring station any and all service work to qualified experts 4 2 Replacing the batteries 20 RESET button restore factory settings MRFI FSSTHFRMtlMFTFR 21 Opening for wall mounting 22 Battery compartment Keep the packaging material out of the reach of children due to the risk of suffocation Dispose of packaging material immediately according to locally applicable regulations Thank you for choosing a Hama product Take your time and read the following instructions and information Do not modify the product in any way Doing so voids the Buy special or suitable installation material from a specialised dealer for wall mounting Measuring station Open the battery compartment 22 remove and properly dispose of the dead batteries and insert two new AA batteries with the correct polarity Replace the battery compartment cover warranty Ensure that no faulty or damaged parts are installed Never apply force during installation This could damage the product Before installation ensure that the chosen wall is suitable for the weight to be mounted and make sure that there completely Please keep these instructions in a safe place for Base station are no electrical wires water gas or other lines at the future reference If you sell the device please pass these operating Open the battery compartment 18 remove and properly installation site on the wall instructions on to the new owner dispose of the dead batteries and insert two new AAA batteries with the correct polarity Replace the battery compartment cover 1 Explanation of Warning Symbols and Notes 5 1 Base station Use the base 19 to position the base station on a level surface Alternatively you can install the base station on a wall using the opening 17 on the back Before use ensure you insert the batteries in the measuring This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks station first and then in the base station 5 2 Measuring station You can also position the measuring station on a level outdoor surface using the base 19 We recommend installing the measuring station securely on an outdoor wall Install an anchor screw nail etc in the wall of your choice 2 3