Hama ews-280 [3/11] Note replacing the batteries

Setting the time zone Weather forecast 6 5 Low battery charge Based on changes in the atmospheric pressure and the data saved the base station is able to make weather forecasts for the next 12 to 24 hours Note Weather forecast Press and hold the button 14 again for approx 3 seconds to stop the manual search The radio symbol 4 disappears The clock automatically switches to summer time 0 appears on the display as long as summer time is activated Manually setting the date time Press and hold the A button 18 for approx 3 seconds to stop the search for the DCF signal The wireless icon 4 disappears and you can set the time manually Repeatedly press the MODE button 13 until the time zone symbol 6 is no longer displayed Press and hold the MODE button 13 for approx 3 seconds to make the following settings one after the other Day of the week 10 Year 5 Month 7 Day 7 D M M D 7 display 12 24 hour format 5 Hours 5 Minutes 5 To select individual values press the button 14 or the button 17 and confirm each selection by pressing the MODE button 13 Press the MODE button 13 immediately to adopt the set value displayed and skip ahead If you do not make an entry for 2 minutes you automatically exit the setup mode Day of the week You can choose from German DE English EN Swedish SW Dutch DU Spanish SP Italian IT or French FR for the day of the week display 4 Repeatedly press the MODE button 13 until the time zone symbol 6 is displayed Press and hold the MODE button 13 for approx 3 seconds to set the required time zone difference To select individual values press the button 14 or the button 17 and confirm each selection by pressing the MODE button 13 If you do not make an entry for 2 minutes you automatically exit the setup mode Messstation If the batteries need to be replaced the symbol for low battery charge will appear next to the outdoor temperature display on the base device Replace the batteries immediately The weather forecast function is not available during the first few hours of operation because it requires data that is collected during operation The probability of an accurate weather forecast is around 70 This forecast quality applies within around 20 to 30 km of the location If you take the weather station with you when travelling a reliable weather forecast will only be available after 24 hours because the weather station initially has to determine the local weather conditions The weather forecast and the current weather are indicated by different symbols Base station If the batteries need to be replaced the symbol for low battery charge will appear next to the seconds digit on the base device Replace the batteries immediately Note Replacing the batteries Note that the stations have to be resynchronised each time after you change the batteries in the measuring or base station To do this remove the batteries from the other station and then reinsert them or change them as required Alarm 7 Care and Maintenance Repeatedly press the ALARM button 12 to display the different alarms The alarm symbols 11 cis are displayed along with the corresponding alarm times or OFF Press and hold the ALARM button 12 for approx 3 seconds to set the time of the alarm displayed The hours display begins to flash Press the button 14 or theV button 17 to select the hour for the alarm time and confirm your selection by pressing the ALARM button 12 The minutes display begins to flash Repeat the process to set the minutes for the alarm time Press the ALARM button 12 again to set the other alarm mode as well or to return to the time display 5 If you do not make an entry for 2 minutes you automatically exit the setup mode When activated the weekday alarm only triggers an alarm on weekdays Monday to Friday The alarm symbol 10 is displayed if this alarm is activated When activated the once only alarm only triggers an alarm once The alarm symbol 10 G is displayed if this alarm is activated This alarm is automatically deactivated after the alarm has sounded In the corresponding display press the button 14 or the button 17 to activate deactivate the corresponding alarm The alarm symbol 10 will appear not appear If the alarm is triggered the alarm symbol 11 will begin to flash and an alarm will sound Press the alarm button 12 to stop the alarm Otherwise it will stop automatically after 2 minutes Only clean this product with a slightly damp lint free cloth and do not use aggressive cleaning agents 8 Warranty Disclaimer Hama GmbH Er Co KG assumes no liability and provides no warranty for damage resulting from improper installation mounting improper use of the product or from failure to observe the operating instructions and or safety notes 9 Service and Support Please contact Hama Product Consulting if you have any questions about this product Hotline 49 9091 502 115 German English Further support information can be found here www hama com 10 Technical Data At night the sun forecast means a cloudless sky The weather station does not detect fog because fog can occur under various weather conditions Basisstation Messstation Power supply 3 0 V 2 AA batteries 3 0 V 2 AA batteries Trend Measuring range Temperature 20 Cto 60 C 4 Fto 140 F 20 C to 60 C 4 F to 140 F Increasing Measurement increments Temperature 0 1 C 0 2 F 0 1 C 0 2 F Temperature measurement cycle 43 47 s 43 47 s The weather station indicates a trend as to how the values for air pressure 1 are likely to develop over the next few hours Display p RENDIT pREN Constant 6 3 Weather Celsius Fahrenheit Radio controlled DCF dock Yes No Dimensions WxHxD 8 7 x 18 4 x 2 7 cm 8 7 x 2 7 x 18 4 cm Weight without batteries 198g 60 g pREND Decreasing Press the C F button 15 to choose between C and F for the temperature display 6 4 Maximum and minimum temperature and humidity values The base station automatically stores the maximum and minimum outdoor indoor temperature values Repeatedly press the MEM button 16 to switch between the current temperature minimum temperature MIN and maximum temperature MAX Press and hold the MEM button 16 for approx 3 seconds to reset the stored maximum and minimum values Frequency 433 MHz Range 30m 5