YLI YK-168 [3/4] Operation of the control station
![YLI YK-168 [3/4] Operation of the control station](/views2/1251419/page3/bg3.png)
3
www.yli.cn
We create security
A. Single User Code (Common User Code)
PRESS KEY 5 00 Enter the User Code (4-8 digits) #
Deleting the common User Code
When enter new common User Code the old one will be deleted automatically
B. Multi-User Codes
PRESS KEY 5 01 Enter the User Number (3 digits) Enter the User Code (4-8 digits) # (Confir-
ming the code length) (Green LED flash) # (Green LED stop flash) (confirmed entering is completed)
NOTE: 1. If continue to record more User Codes, at the end of each recording, it is no necessary to press the
key # per each time, to repeat the above steps until all User Code recordings are finished. Finally to press
the key # to confirm all recording are completed.
2. The User Number of the User Code and the User Number of the User ID Card must be the same,i.e.the User
Number of the User Code is 008,the User Number of the User ID Card is also 008,so in Card + Code
operation mode the User Number of both the User ID Card and User Code can be matched in application.
Deleting the User Code recorded (Multi-User Code)
*
PRESS KEY 5 02 0000 # (Deleted all the User Codes)
PRESS KEY 5 02 Enter the User Code to be deleted # (Deleted the User Code)
PRESS KEY 5 02 Enter the User Number of the User Code # (Deleted the User Code of the User
Number)
OPERATION OF THE CONTROL STATION
(8)Programming User Code entry mode
(User Code entry mode)
PRESS KEY 70 0
#
(Manual entry mode, have to press the key follow the User Code entered to
#
confirm the code length of the User Code entered. The User Code can be 4-8 digits)
PRESS KEY 70 1 # (Auto entry mode, the User Code must be set in the same code length as the
program code. No need to PRESS KEY # to confirm the code length of the User Code entered.
The User Code can 4-8 digits)
NOTE: Factory setting anual code entry mode
(9)End of programming
Exit programming mode in 60 seconds
PRESS KEY to exit programming mode and return to normal operation status(Standby mode)
*
NOTE: The amber LED 1 flash in 2 second interval-the control station is in normal operation mode,
standby for use.
(1) Open door by User ID Card (Door opened by reading User ID Card)
(2) Open door by User Code (Door opened by entering User Code)
(3) Open door by User ID Card User Code (Door opened by reading User ID Card, green LED will flash,
in 10 seconds entering the User Code)
SAFETY FUNCTIONS
(1) Entry of 10 false codes or reading 10 invalid ID Cards, the control station locks for 30 seconds.
(2) In case tamper switch is activated, warning signal is indicated: amber LED continuous flash and
buzzer continuous beeps, until tamper switch is deactivated.
Control station in locking state:
No response to ID Card / or key entry, amber LED and green LED show 1 flash and buzzer sounds 1 short
beep in 10 seconds interval, at the end of locking the buzzer sounds 1 long beep to signify the end of locking
and return to normal operation mode.
RESTORING THE DEFAULT PROGRAMMING CODE
If the programming code is lost (or unknown), use the DAP jumper to restore the default programming code,
procedures as follows:
(1)Disconnect power supply.
(2)Put the DAP jumper from OFF position to ON position.
(3)Reconnect power supply, amber LED will flash constantly and the buzzer will beep constantly.
(4)Put the DAP jumper back to OFF position, amber LED will stop flashing, buzzer will stop beep.
(5)The default programming code 1234 is restored.
Содержание
- Audible visible indications 1
- Introduction 1
- Model yk 168 1
- Rfid digital keypad control station 1
- Technical data 1
- Www yli cn we create security 1
- Alarm status 2
- During programming 2
- Press key 3 01 open door by user id card or user code c press key 3 02 open door by user id card user code 6 programming the door open time press key 4 01 99 seconds setting door opening time 1 99 seconds note factory setting door opening time is 3 seconds 7 recording the user code 2
- Procedures of programming 2
- Programming 2
- Programming confirmation press key 2
- Www yli cn we create security 2
- A single user code common user code press key 5 00 enter the user code 4 8 digits deleting the common user code 3
- Operation of the control station 3
- Restoring the default programming code 3
- Safety functions 3
- Www yli cn we create security 3
- 1 the control station controls the apparatus via power supply 4
- 2 the control station directly controls the connecting apparatus note max rating of relay contact current 3a 24vdc 4
- Notice to installer 4
- Wiring diagram 4
- Www yli cn we create security 4
Похожие устройства
- YLI YK-268 Инструкция по эксплуатации
- LG VS8706SCM Руководство пользователя
- LG VS8606SCM Руководство пользователя
- LG VS8401SCW Руководство пользователя
- LG VSF8405SC Руководство пользователя
- LG VR6570LVMB Руководство пользователя
- LG VR6570LVMP Руководство пользователя
- LG VRF6540LV Руководство пользователя
- LG VRF6570LVM Руководство пользователя
- LG VRF6570LVMB Руководство пользователя
- LG VRF4033LR Руководство пользователя
- LG VRF6043LR Руководство пользователя
- LG MW25R35GIH Руководство пользователя
- LG MW23W35GIB Руководство пользователя
- LG MW23R35GIB Руководство пользователя
- Daikin FTXG20LW_RXG20L Инструкция по эксплуатации
- Daikin FTXG20LW_RXG20L Инструкция по монтажу (нар. блок)
- Daikin FTXG20LW_RXG20L Инструкция по монтажу (внутр. блок)
- Daikin FTXG25LW_RXG25L Инструкция по эксплуатации
- Daikin FTXG25LW_RXG25L Инструкция по монтажу (нар. блок)
Скачать
Случайные обсуждения