Pontec PondoAir Set 450 [11/92] Installation and connection

Pontec PondoAir Set 450 [11/92] Installation and connection
- GB -
11
Installation and connection
B, C, D
Set-up the unit
Install the unit flood protected in a horizontal position.
Ensure that the unit is installed with a safety distance of at least 2 m from the water.
Install the unit above the level of the water, otherwise it will be damaged by water flowing back.
Damage resulting from incorrect installation is not basis for a claim within the framework of the guarantee or warranty.
Connect the unit
Keep the air hose as short as possible and lay it well protected.
Connect the aeration stone to the air hose and position the aeration stone in the pond.
Attach the free end of the air hose to the air outlet on the unit.
Start-up
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Remedy of faults
Malfunction Cause Remedy
The unit is not operating No mains voltage Check mains voltage
The aeration stones are soiled Clean or replace the aeration stones
The air filter is soiled Clean or replace the air filter
Air hose kinked or porous Lay the air hose without kinks or replace
The unit does not deliver any air or the amount
delivered is insufficient
Membrane is defective Replace both membranes
The unit is unusually loud Membrane is defective Replace both membranes
Wear parts
Aerator stones, air filter and membranes are wear parts and are not covered by our warranty.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the
water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Cleaning the air filter
3.
0.
How to proceed:
E
1. Remove the filter holder from the top section of the housing with the aid of a screwdriver.
2. Remove and shake out the filter fleece or replace if necessary.
3. Push the filter fleece into the filter holder.
Pay attention to the O ring as it holds the filter holder in the housing.
4. Reassemble the unit in the reverse order.
23589-12-13_GA_PondoAir Set 200-11 11 04.12.2013 10:12:57

Содержание