Pontec PondoAir Set 450 [12/92] Disposal

Pontec PondoAir Set 450 [12/92] Disposal
- GB -
12
Replace membranes
An aerator motor is located under the aerator housing. If the delivery rate of the aerator pump decreases, it is necessa-
ry to replace the two membranes. To do this it is necessary to open the housing and remove the aerator motor.
Note!
Never operate the unit with defective membranes.
Always replace both membranes even when only one membrane is defective. The procedure is identical for
both membranes.
Please contact your specialist dealer if you do not wish to undertake the replacement yourself.
Opening the housing
F
Undo the screws on the bottom section of the housing and remove the top section of the housing from the bottom
section.
Removing the aerator motor
5.
0.
How to proceed:
G
1. Unscrew the screws from the base of the aerator motor.
Slightly bend the membrane clip sideways if necessary.
2. Remove the aerator motor.
There will be initial resistance caused by the two air outlets fastened to the housing.
Replace membranes
3.
0.
How to proceed:
H
1. Undo and remove the nut from the membrane clip.
2. Hinge the membrane clip to the side.
3. Fit the new membrane.
4. Fit the screws.
5. Close the membrane clip.
6. Fit the nut and tighten.
Fitting the aerator motor
7.
0.
How to proceed:
I
1. Place the aerator motor into the housing.
Ensure that the air outlets are equipped with sealing rings.
During fitting, there will be initial resistance from the two air outlets.
2. Screw the aerator motor in place.
Closing the housing
J
Place the top section of the housing onto the bottom section and screw on.
Ensure that the strain relief of the power connection cable is correctly located in the recess of the housing.
Storage/Over-wintering
When the unit is in continuous operation it can remain in place at freezing temperatures.) Otherwise store the unit
indoors in a dry room (room temperature).
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
23589-12-13_GA_PondoAir Set 200-12 12 04.12.2013 10:12:57