Stiebel Eltron DHF 24 C [12/52] Operating instructions

Stiebel Eltron DHF 15 C [12/52] Operating instructions
12
1.5 Setting recommendation
# Operation with twin-handle fitting:
""
""
" Wash basin:
Half heating output, select !.
""
""
" Bath, shower or sink:
Maximum heating output, select !!.
If in spite of the hot water tap being
fully open the temperature is too high,
cold water must be mixed in.
# Operation with one-hand mixer:
""
""
" Wash basin:
Half heating output, select !.
""
""
" Bath, shower or sink:
Maximum heating output, select !!.
Turn lever of fitting fully to ”hot”.
Fully open fitting
Increase temperature by slowly closing
the fitting
Reduce temperature by mixing in cold
water or, if possible by opening the
fitting further.
# Operation with thermostatic fitting:
""
""
" Maximum heating output, select !!.
Follow the instructions of the fitting
manufacturer.
1.6 First actions to be taken
in the event of malfunc-
tion
" Check the fuses
" Check the fittings and shower heads for
lime scale blockage or dirt accumulation.
See also ”3. Fault finding by the user”.
1.7 Maintenance and care
Maintenance work, such as for
example checking the electrical
safety, may only be carried out by a quali-
fied installer.
A damp cloth is sufficient for care of the unit.
Do not use any abrasive or corrosive clean-
ing agents.
1.8 Operating and installa-
tion instructions
Keep these instructions carefully and
pass them on to your successor in
the event of a change in ownership, in the
event of maintenance and possible repair
work they should be passed to the quali-
fied installer for his attention.
1.3 Important instruction
In the case of temperature selection,
water temperatures of over 55 °C
can be reached at the hot water outlet.
High temperatures can be achieved if the
unit is switched off and then on again
quickly. Small children should therefore be
kept away from the hot water outlets.
Danger of scalding!
If the water feed of the DHF ... C has
been interrupted - e.g. because of the dan-
ger of frost or work on the water pipe, the
following steps must be taken before the
unit is brought back into operation:
1. Remove or switch off fuses.
2. Open a tap downstream of the unit
until the unit and the cold water feed
pipe are free of air.
3. Replace or switch on fuses again.
1.4 Hot water output
According to the time of year, the following
maximum mixed water quantities or outlet
quantities are delivered, in the case of various
cold water temperatures (see Table 1):
#
1
= cold water feed temperature
#
2
= mixed water temperature
#
3
= outlet temperature.
" Useful temperature:
approx. 38 °C: e.g. for showers, hand was-
hing, bathing etc.
approx. 55 °C: for dishwashing and when
using thermostatic fittings.
1.1 Unit description
The hydraulically controlled instantaneous
water heater DHF … C compact control
heats the water as it is flowing through the
unit. As soon as a hot water tap is turned on,
the heating output is switched on
automatically after the switch-on quantity is
exceeded. The temperature of the hot water
is dependent on the flow rate and
temperature of the incoming cold water.
1.2 The main points in brief
Output selector
! Half heating output
Only half the heating output is switched
on:
""
""
" suitable e.g. for hand washing.
!! Maximum heating output
With a low flow rate half the heating
output is switched on, at a higher flow
rate the full heating output is
automatically switched on:
""
""
" suitable e.g. for bathing, showering or
washing up.
Low tap quantity
""
""
" high outlet temperature.
High tap quantity
""
""
" low outlet temperature.
If with the tap fully opened the required
outlet temperature is not reached, more
water is flowing through the unit than the
heating element can heat (output limit 12,
13, 15, 18, 21 or 24 kW). In this case the
water quantity at the hot water tap must
be reduced accordingly.
At outlet temperatures of over 43 °C
there is a risk of scalding.
1. Operating instructions for the user and qualified installer
Table 1
* The actual outlet quantity is dependent on
the available supply pressure.
#
2
= 38 °C (mixed water temperature)
kW 12 13.2 15 18 21 24
#
1
l/min *
10 °C 6.1 6.8 7.7 9.2 10.7 12.3
14 °C 7.2 7.9 9.0 10.7 12.5 14.3
#
3
= 55 °C (outlet temperature)
kW 12 13.2 15 18 21 24
#
1
l/min *
10 °C 3.8 4.1 4.8 5.7 6.7 7.6
14 °C 4.2 4.6 5.2 6.3 7.3 8.4

Содержание

1 Operating instructions for the user and qualified installer 1 1 Unit description The hydraulically controlled instantaneous water heater DHF C compact control heats the water as it is flowing through the unit As soon as a hot water tap is turned on the heating output is switched on automatically after the switch on quantity is exceeded The temperature of the hot water is dependent on the flow rate and temperature of the incoming cold water 1 2 The main points in brief Output selector Half heating output Only half the heating output is switched on suitable e g for hand washing Maximum heating output With a low flow rate half the heating output is switched on at a higher flow rate the full heating output is automatically switched on suitable e g for bathing showering or washing up Low tap quantity high outlet temperature High tap quantity low outlet temperature If with the tap fully opened the required outlet temperature is not reached more water is flowing through the unit than the heating element can heat output limit 12 13 15 18 21 or 24 kW In this case the water quantity at the hot water tap must be reduced accordingly At outlet temperatures of over 43 C there is a risk of scalding 1 3 Important instruction 1 5 Setting recommendation Operation with twin handle fitting Wash basin X In the case of temperature selection water temperatures of over 55 C can be reached at the hot water outlet High temperatures can be achieved if the unit is switched off and then on again quickly Small children should therefore be kept away from the hot water outlets Half heating output select Bath shower or sink Maximum heating output select If in spite of the hot water tap being fully open the temperature is too high cold water must be mixed in Danger of scalding Operation with one hand mixer Wash basin If the water feed of the DHF C has been interrupted e g because of the dan ger of frost or work on the water pipe the following steps must be taken before the unit is brought back into operation 1 Remove or switch off fuses 2 Open a tap downstream of the unit until the unit and the cold water feed pipe are free of air 3 Replace or switch on fuses again Half heating output select Bath shower or sink Maximum heating output select Turn lever of fitting fully to hot Fully open fitting Increase temperature by slowly closing the fitting Reduce temperature by mixing in cold water or if possible by opening the fitting further Operation with thermostatic fitting 1 4 Hot water output According to the time of year the following maximum mixed water quantities or outlet quantities are delivered in the case of various cold water temperatures see Table 1 cold water feed temperature mixed water temperature dj outlet temperature Useful temperature 1 7 Maintenance and care Üj 3 8 C mixed water temperature 12 13 2 l min 15 10 C 14 C 6 1 6 8 7 7 7 2 7 9 9 0 18 21 24 X Maintenance work such as for t I example checking the electrical 9 2 110 7 112 3 safety may only be carried out by a quali fied installer 10 7 12 5 114 3 A damp cloth is sufficient for care of the unit Do not use any abrasive or corrosive clean ing agents Ôj 55 C outlet temperature kW 10 C 14 C 12 13 2 15 18 21 24 l min 3 8 4 2 4 1 4 8 5 2 1 6 First actions to be taken in the event of malfunc tion Check the fuses Check the fittings and shower heads for lime scale blockage or dirt accumulation See also 3 Fault finding by the user approx 38 C e g for showers hand was hing bathing etc approx 55 C for dishwashing and when using thermostatic fittings kW Maximum heating output select Follow the instructions of the fitting manufacturer 5 7 6 3 6 7 7 3 7 6 8 4 Table 1 1 8 Operating and installa tion instructions The actual outlet quantity is dependent on the available supply pressure A Keep these instructions carefully and 1 pass them on to your successor in 4 6 the event of a change in ownership in the event of maintenance and possible repair work they should be passed to the quali fied installer for his attention 12