Dometic MCS 16T [7/412] Operating

Dometic MCS 6T [7/412] Operating
EN
MCS6, MCS12, MCS16 Operating
7
6.2 Dual Button Functions
Up and Down Buttons
While in the On Mode: Simultaneously press the Up and Down Buttons
to display outside air temperature providing the optional outside air tem-
perature sensor is installed.
While in the Program Mode: Simultaneously press the Up and Down
Buttons to set new program defaults.
Power and Down Buttons
While viewing the service fault history log: Simultaneously press the
Power and Down Buttons to clear the fault history log (see “Service His-
tory Log” on page 13).
While in the On Mode: Simultaneously press the Power and Down
Buttons to enter the Moisture Mode (see “Moisture Mode” on page 10).
7 Operating
7.1 Initial startup
A
NOTICE!
Do not turn the unit off and immediately turn it back on. Allow at
least 30 s for refrigerant pressure equalization.
Ensure seawater intake ball valve (seacock) is open.
Make sure the control is powered OFF.
Turn on air conditioner circuit breaker.
If the seawater pump has its own circuit breaker, turn that on too.
8 LED “Fan Indicator” This LED is lit when a Manual Fan Speed is
selected.
9 LED “Cool Mode” This LED is lit when
– the Cool Only Mode is selected
– or when the unit is in a cooling cycle.
Item Name Description