Timberk AC TIM 07H S18A [5/17] Operating modes

Timberk AC TIM 07H S18A [5/17] Operating modes
www.timberk.com • Electric air conditioner www.timberk.com • Electric air conditioner
8
9
8. MAINTENANCE
«SUPER» mode (TURBO)
When pressing the «TURBO» button on the remote control board, the
conditioner will start working in turbo mode – for maximum cooling (in cool
mode) or for maximum heating (in heat mode).
TIMER mode
Procedure of timing:
– If the conditioner is off, then press the “TIMER” button to activate the
automatic turning on. Pressing this button once again, set the time for
turning the conditioner on in the set time interval. To cancel the timer mode,
press the “TIMER” button once again.
–If the conditioner is working, then press the “TIMER” button to activate
the automatic turning off. Pressing this button once again, set the time for
turning the conditioner off in the set time interval. To cancel the timer mode,
press the “TIMER” button once again.
«SLEEP» mode
Button «SLEEP» (Night Care). Using this button, you may turn the sleep
mode on and off. In this mode, if working for cooling, the conditioner will
increase temperature by 1 °С an hour from the specified one within two
hours. If working for heating, the conditioner will decrease temperature by
1 °С an hour from the specified one within two hours. After 10 hours of
operation the conditioner will turn off automatically.
Regulation of treated air flow direction
Regulating the position of deflectors (blinds), set the direction of treated
air flow ensuring uniform distribution of temperature and the most comfort
conditions in the room. To change the position of deflectors, use the
«SWING» button.
AUTO mode (SMART)
The auto mode is turned on and off with the use of the button “MODE” on
the remote control board.
1. While working in the AUTO mode, a microprocessor will automatically
select COOL, FAN, HEAT or DRY modes based on the difference between
actual and preset air temperature indoors.
2. If the AUTO mode does not provide comfort conditions, select the mode
manually. In automatic mode, depending on air temperature in the room,
the conditioner will select needed temperature parameters of its operation
in the following order:
7. OPERATING MODES
Temperature indoors Automatic mode sele ction Automatically maintained temperature
if <20° С then HEAT mode shall be turned on 23° С
if <20° С - 26° С then DRY mode shall be turned on 18° С
if <26° С
then COOL mode shall be turned on
23° С
ASmart mode allows changing threshold of switching from mode to mode.
During operation in Smart mode you see «-» on the display. Press keys
Temp +/-. «-» will change by +(-) 2. The range shift of this threshold
ASmart mode allows changing threshold of switching from mode to mode.
During operation in Smart mode you see «-» on the display. Press keys
Temp +/-. «-» will change by +(-) 2. The range shift of this threshold is within
-2...+2 of default temperatures.
COOL, HEAT and FAN
1. Turn the conditioner on pressing the «ON/OFF» button.
2. Pressing the «MODE» button, select COOL, HEAT or FAN mode
manually.
3. Pressing the «TEMP» button (up-down), set the desired air temperature
indoors (except for FAN mode).
4.Pressing the «FAN SPEED» button on the remote control board, select
the fan rotation speed: AUTO, LOW, MIDDLE, HIGH, and the conditioner
will start working in accordance with the selected setting. In the Smart
mode fan speed automatically selected.
5.To turn the conditioner off, press the «ON/OFF» button once again.
• Before cleaning unplug the conditioner.
• Cleaning of the indoor unit and remote control board:
• Indoor unit and remote control board should be cleaned with a dry soft
cloth.
• If the indoor unit is too unclean, moisten the cloth with cold water.
• It is prohibited to clean the remote control board with moist cloth.
• In order to avoid the damage of paint or details of the conditioner, do not
clean it with brushes and do not leave them on the surface of indoor unit.
• In order to avoid the damage of surface or deformation of the conditioner
details, do not clean it with petrol, solvents, cleaning powders or other
chemically active substances.
• Before a sustained interruption in the conditioner work:
• Turn the conditioner on for several hours in the FAN mode. It will allow
you to dry its inner cavities
• Unplug the conditioner. Remove the batteries from the remote control
board.
• Checks before starting:
• Make sure that an air filter is installed.
• Make sure that air inlet and outlet grilles of the outdoor unit are not
blocked by foreign objects.
• Cleaning of air filter
• Air filter cleans the air entering the conditioner from dust and foreign
particles. If the filter is contaminated, the conditioner capacity decreases
sharply.
• If the conditioner is operated permanently, the filter should be cleaned
once per two weeks.
• If the conditioner is installed in a room with dusty atmosphere, then the
air filter should be cleaned more often.
• To remove the filter, open the indoor unit panel.
• Remove air filters. Clean the filter with a vacuum cleaner or rinse it in
clean water. If the filter is contaminated heavily, clean it with a soft brush
and wash in diluted washing solution, then dry it in a cool place.
• While cleaning the filter with the vacuum cleaner, hold it with contaminated
surface up. While washing the filter in water, hold it with contaminated
surface down.
• Do not dry the filter in the sun or near a fire.
• Set the air filter to initial position and close the panel.
In the FAN mode air temperature indoors is not set.
DRY
Turn the conditioner on pressing the «ON/OFF» button. Pressing the
«MODE» button, select the DRY mode. The conditioner will start working
in the set mode. To turn the conditioner off, press the «ON/OFF» button
once again.
9. TROUBLESHOOTING
In case of emergency, please, use the troubleshooting methods shown in
tables. If it is impossible to solve problems with these methods, apply to
the service center.
Failures and their possible reasons:
Failure Possible reason Actions
The conditioner does
not work
Interruptions in power supply
Wait for restoration of power
supply
Batteries in the remote control
board are low
Replace the batteries
Time of tuming on is set by
the timer
Wait till the conditooner turns
on by the timer or cancel the
timer setting
Insufficient cooling or
heating capacity
The set air temperature is too
high or too low
Set the air temperature
correctly
The air filter is clogged with dust Clean the air filter
Foreign objects block the air intel
and retum air grillages of the
outdoor unit
Remove foreign objects
The conditioner works,
but does not cool or
heat the room
A three-minute delay of
compressor tuming on
Wait a little
The air temperature is set
incorrectly
Set the temperature correctly

Содержание