ORAS Electra 6100 [11/48] Cleaning the filter see figures 1 and 2

ORAS Electra 6100 [11/48] Cleaning the filter see figures 1 and 2
Cleaning the Filter (see Figures 1 and 2)
If the water flow has decreased, this may be because the filter is clogged. Clean the filter as follows:
Shut off the water supply to the faucet.
Remove the connecting hose (7) from the control box.
Unscrew the connecting nipple (8) and remove the strainer from the nipple.
Clean the strainer under running water.
Reassemble the parts.
Troubleshooting
Symptom Cause / Solution
Water flow from the outlet The sensing range is too low
does not stop, or stops Check that the photocell is clean
after 40 seconds The solenoid valve is damaged
Water flow is low and weak Filter is clogged
No water comes out of the faucet Check the water supply to the control box
The solenoid valve is damaged
Power failure
The sensor is covered or damaged
Check the fuse (17) inside the control box:
6100: 0.1 A
6130: 1 A
11 (48)