ORAS Electra 6568 [12/52] Changing the pilot valve

12
Installation
6567:
The stop valve is installed as shown in fi gure 1. The stop then points to the right
(seen from ahead).
6568:
Electra is installed to G3/4 anglefi tting as shown in fi gure 1.
6567, 6568:
Rinse the pipes (fi gure 2).
Set the urinal fl usher in place but do not lock it to the stop valve. Measure the distance from the
upper edge of the urinal to the fl usher (fi gure 3). Then detach the fl usher from the stop valve.
Cut the fl ushing pipe to correct length (fi gure 4).
Put the urinal’s connection packing in place (fi gure 5).
Figure 6:
Connect the fl usher pipe to the outlet (1) and install the fl usher in place on the urinal (2) and
attached to the stop valve (3).
6567:
Attach the fl usher to the stop valve with the hexagonal screw.
6568:
Filter packing is placed into the inlet union
Attach the fl usher to the anglefi tting.
6567, 6568 Figure 7:
Remove the tape from the sensor lenses.
Open the stop valve and make sure the fl usher operates correctly.
Installation instructions for spare parts
Changing the battery
Figure 8:
Undo the fl usher cover locking screw (3).
Detach the fl usher cover by lifting it simultaneously up and outwards.
Figure 9:
Undo the battery casing cover (1) screws (2) and detach the cover.
Change the battery.
Reassemble in reverse order.
Changing the sensor
Figure 8:
Undo the fl usher cover locking screw (3).
Detach the fl usher cover by lifting it simultaneously up and outwards.
Figure 9:
Detach the sensor connector (4) from the solenoid valve connector (5).
Undo the battery casing cover (1) screws (2) and detach the cover.
Undo the sensor locking screws (3) and detach the sensor.
Attach the sensor in place.
Reassemble in reverse order.
Changing the pilot valve
Close the water inlet to the fl usher.
Figure 8:
Undo the fl usher cover locking screw (3).
Detach the fl usher cover by lifting it simultaneously up and outwards.
Figure 9:
Detach the sensor connector (4) from the solenoid valve connector (5).
Undo the solenoid valve locking screws (6) and detach the solenoid valve (7).
Attach the new solenoid valve in place.
Reassemble in reverse order.
Open the water inlet to the fl usher.

Содержание

Похожие устройства

Installation 6567 The stop valve is installed as shown in figure 1 The stop then points to the right seen from ahead 6568 Electra is installed to G3 4 anglefitting as shown in figure 1 6567 6568 Rinse the pipes figure 2 Set the urinal flusher in place but do not lock it to the stop valve Measure the distance from the upper edge of the urinal to the flusher figure 3 Then detach the flusher from the stop valve Cut the flushing pipe to correct length figure 4 Put the urinal s connection packing in place figure 5 Figure 6 Connect the flusher pipe to the outlet 1 and install the flusher in place on the urinal 2 and attached to the stop valve 3 6567 Attach the flusher to the stop valve with the hexagonal screw 6568 Filter packing is placed into the inlet union Attach the flusher to the anglefitting 6567 6568 Figure 7 Remove the tape from the sensor lenses Open the stop valve and make sure the flusher operates correctly Installation instructions for spare parts Changing the battery Figure 8 Undo the flusher cover locking screw 3 Detach the flusher cover by lifting it simultaneously up and outwards Figure 9 Undo the battery casing cover 1 screws 2 and detach the cover Change the battery Reassemble in reverse order Changing the sensor Figure 8 Undo the flusher cover locking screw 3 Detach the flusher cover by lifting it simultaneously up and outwards Figure 9 Detach the sensor connector 4 from the solenoid valve connector 5 Undo the battery casing cover 1 screws 2 and detach the cover Undo the sensor locking screws 3 and detach the sensor Attach the sensor in place Reassemble in reverse order Changing the pilot valve Close the water inlet to the flusher Figure 8 Undo the flusher cover locking screw 3 Detach the flusher cover by lifting it simultaneously up and outwards Figure 9 Detach the sensor connector 4 from the solenoid valve connector 5 Undo the solenoid valve locking screws 6 and detach the solenoid valve 7 Attach the new solenoid valve in place Reassemble in reverse order Open the water inlet to the flusher 12