Denyo DCA-800SPK [3/12] Performance features

Denyo DCA-800SPK [3/12] Performance features
The Denyo generating system
guarantees the following levels
of performance:
TEMPERATURE RISE:
100 temperature
rise at 40 ambientJEC2130.
INSULATION:ClassFJEC2130.
VOLTAGE REGULATION:
Within±0.5%
(exceptDCA-400SP)
FREQUENCY REGULATION:
Within5.0%
throughno-loadtofull-load.
VOLTAGE WAVEFORM:
DeviationFactorof
open-circuitterminalvoltagedoesnot
exceed0.06.
TelephoneInfluenceFactor(TIF)islessthan
50.
ELECTROMAGNETIC INTERFERENCE
LEVEL:
Attenuatedtomeetmostcommercial
requirements.
INSULATION RESISTANCE:
Higher than 3
Mega-ohms, measured between armature
windings and earth, field windings and earth,
field control circuit and earth.
The innovative excitation system* fitted on
all models, in conjunction with the AVR and
advanced brushless generator, provides fast
voltage regulation in response to load
variations, enabling use soon after start up.
This system provides output stability during
load variations.
*U.S.Patent No.4268788
Synchronous brushless alternator for
minimal wear.
Designed to function in all climatic
conditions.
Easy starting and quick response.
Utilising highly reliable diesel engines with
low fuel consumption, manufactured by
Japan's leading engine manufacturers.
TRUE HEAVY-DUTY PERFORMANCE
For a particular job, you may need that extra
power from your generator. With the DCA
Series, the standby power rating110% or
105% load except DCA-610SPMcan be
used continuously for 1 hour in every 8 hours
of continuous operation.This extra power
performance of Denyo generators means
you can get the job done, without the
inconvenience of using another generator.
PERFORMANCE
FEATURES
ECONOMICAL
PERFORMANCE
UNSURPASSED
FLEXIBILITY
HIGH-PERFORMANCE
Will safely power the most sensitive loads,
such as thyristors, invertors and computer
systems, without the risk of damage to these
loads, thanks to the high level electrical
characteristics of the generator's output.
To meet today's varying needs
successfully, your equipment
must be as flexible as you are. The
Denyo DCA Series generator
range provides you with the
flexibility to get the job done
simply and economically, without
any delays.
PARALLEL OPERATION FEATURE
(except for
DCA-100 and below
)
From time to time, at a construction site, mine
site or in other situations, a large temporary
power supply is required for a particular job.
To meet this requirement Denyo's DCA Series
generators incorporate a built-in parallel
operation drive system, allowing you to create
a largecapacity generating plant on-site,
without the need to procure any other
equipment.
DUAL VOLTAGE SYSTEM
optional for DCA-25USI3, 45ESI, 45USI2, 60ESH, 60USH
For companies that operate internationally or
have motors that require power at different
voltages, a different generator is usually
required for each voltage setting. However,
the DCA Series generators are equipped with
a dual voltage system, so one generator can
be used to power motors with different
voltage settings. An extremely convenient
feature.
ALL MODELS CAN RUN AT 50Hz/60Hz
Simply adjust the engine speed on the
control panel to use a DCA Series generator
at either 50 Hz or 60 Hz.
EXTREMELY QUIET OPERATION
In urban areas and at the worksite, there is
an ever increasing demand for reduced noise
pollution. In response to these concerns,
Denyo has pioneered a soundproof and
super soundproof range of generators. The
DCA Series generators are extremely quiet
when operating at full load, even though all
soundproof models are compactly designed.
Check the specifications for the sound level
of each model.
2

Содержание

Похожие устройства