megaSun Optima Deluxe [4/63] Service plan

megaSun Optima Deluxe [4/63] Service plan
5
Service hours What has to be done? see
Every day Check the lling level of the condensate tank and empty it if
necessary.
100 Change or clean lter mats 5.7
500 - 600 Change burners
For inductive apparatuses:
Change tubes
Change starters
Reset counter of service hours
5.4
For CPI-apparatuses (with burners) in Power-mode:
Change tubes
Reset counters (8.2.2)
Reset counter of service hours
Check and grease ropes of the canopy drive 5.8
Check all inner tubes and – if necessary – change them.
Climatic apparatus:
Clean heat exchanger
Check the functioning of the condensate pump
5.10
600
Replace lamps of the shoulder tanner. 5.5
800 For CPI-apparatuses (with burners) in Eco-mode or for CPI-
apparatuses (without burners) in Power-mode:
Change tubes
Reset counters (8.2.2)
Reset counter of service hours
1000 For CPI-apparatuses (without burners) in Eco-mode with
megaSun CPI-tubes in Power-mode:
Change tubes
Reset counters (8.2.2)
Reset counter of service hours
5.4
Replace aquaCool nozzles.
5.15
1200 For CPI-apparatuses with megaSun CPI-tubes in Eco-mode
Change tubes
Reset counters (8.2.2)
Reset counter of working hours
3000 Replace all the ropes 5.8
Operation and Service megaSun 5600
2. Service Plan
Service intervals
For a safe operation of the sunbeds, regular service works are
essential and have to be documented. Cleaning works have to
be done when necessary and do not have to be documented.

Содержание

Похожие устройства

Скачать