Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the
type plate. The position of the type plate is shown in the section
entitled Description of the appliance.
Thesocketmustbeproperlyearthedandprotectedbyafuse.
The tripping current of the fuse must be between 10 A and 16 A.
Thesocketmustnotbesituatedbehindtheappli-
ance and must be easily accessible.
Donotconnecttheapplianceusinganexten-
sioncableorextensionsocket.
Donotusestand-aloneinverters(conversion
of direct current to alternating/three-phase
current)orenergy-savingplugs.Riskofdam-
agetotheelectroniccontrolsystem!
Appliance dimensions
Setting up
• Avoidpositioningtheapplianceindirectsunlightornearcookers,
radiators and similar sources of heat.
• Theflooronwhichtheappliancestandsshouldbe
horizontal and level. Compensate for uneven floors
with the adjustable feet.
To alter the height, rotate the bottom
section of the respective adjustable foot.
WARNING!
The height of the foot can be adjusted from 120 mm
to 170 mm.
Do not set the adjustable foot to a
height greater than 170 mm! The
bottom section of the adjustable
foot can become loose and the appliance may
then tip over.
This can lead to serious or even fatal injuries.
• StandardEN378specifiesthattheroominwhich youinstall
your appliance must have a volume of 1 m
3
per 8 g of R 290a
refrigerant used in the appliance, so as to avoid the formation of
inflammable gas/air mixtures in the room where the appliance is
locatedintheeventofaleakintherefrigerantcircuit.Thequantity
of refrigerant used in your appliance is indicated on the type plate
on the inside of the appliance.
• Theremustbeagapofatleast30cm
between the upper edge of the appliance
and the ceiling.
Donotcoverventilationopen-
ings or grille.
Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the
type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating Room temperature
4 (SN) +10°C to +32°C
4 (N) +16°C to +32°C
4+ (ST) +16°C to +38°C
4+ (SN-ST) +10°C to +38°C
5 (T) +16°C to +43°C
5 (SN-T) +10°C to +43°C
Do not operate the appliance outside the
specied room temperature range.
GKPv / BKPv 65.. GKPv / BKPv 84..
GKPv 14..
Содержание
- 681 00 1
- Operating instructions 1
- Content 2
- Description of the appliance 2
- Disposal notes 2
- Gkpv 14 gkpv 65 2
- Stackingmark 2
- Appliance dimensions 4
- Climate rating 4
- Do not operate the appliance outside the specified room temperature range 4
- Do not set the adjustable foot to a height greater than 170 mm the bottom section of the adjustable foot can become loose and the appliance may then tip over 4
- Donotcoverventilationopen ings or grille 4
- Electrical connection 4
- Setting up 4
- The height of the foot can be adjusted from 120 mm to 170 mm 4
- Thesocketmustnotbesituatedbehindtheappli ance and must be easily accessible 4
- This can lead to serious or even fatal injuries 4
- Warning 4
- Bkpv equipment 5
- Equipment 5
- Gkpv 14 equipment 5
- If the cover is removed do not look directly at the light through optical lenses from close distance 5
- Important 5
- Interior light in appliances with glass door 5
- Intermediate shelves 5
- The light cover may only be removed by customer service staff 5
- The light intensity of the led light corresponds to laser class 1 1m 5
- This can damage your eyes 5
- Audible warning signal 6
- Humidity function 6
- Operating and control elements 6
- Setting the temperature 6
- Switching the appliance on and off 6
- Symbols in the display 6
- To switch the appliance off 6
- To switch the appliance on 6
- Cleaning 7
- Cleaning the dust filter 7
- Defrosting 7
- Do not use steam cleaners because of the risk of injury and damage 7
- Malfunctions 7
- Remove the plug 7
- Safety lock 7
- Shutting your appliance down 7
- Changing over door hinges gkpv 65 bkpv 84 8
- If the door is removed and reinstalled in the closed position this will lead to destruction of the self closing mechanism on the first open ing of the door 8
- Warning 8
- If the door is installed in the closed position this will lead to destruction of the self closing mechanism on the first opening and closing of the door 9
- Important 9
- It is essential that the door is open at an angle of 90 during installation 9
- Note on point 12 9
- Warning 9
Похожие устройства
- CAS 3HFS1215 Инструкция по эксплуатации
- Liebherr GKv 6410 Инструкция по эксплуатации
- Liebherr GKv 5730 Инструкция по эксплуатации
- Sikom МК-8.8 (выставочный образец) Инструкция по эксплуатации
- Liebherr WKt 6451 Инструкция по эксплуатации
- CAS 2HFS1212 Инструкция по эксплуатации
- Liebherr GGPv 1470 Инструкция по эксплуатации
- Liebherr FKv 4140 Инструкция по эксплуатации
- Liebherr GKv 5790 Инструкция по эксплуатации
- Liebherr GKv 6460 Инструкция по эксплуатации
- Liebherr GGv 5810 Инструкция по эксплуатации
- Liebherr GGv 5060 Инструкция по эксплуатации
- Liebherr GGPv 1490 Инструкция по эксплуатации
- Liebherr GGPv 6590 Инструкция по эксплуатации
- Liebherr GKPv 1470 Инструкция по эксплуатации
- Liebherr GGv 5860 Инструкция по эксплуатации
- Liebherr LGT 2325 Инструкция по эксплуатации
- Liebherr LGT 2325 Каталог оборудования Liebherr (англ.)
- Liebherr LGT 4725 Инструкция по эксплуатации
- Liebherr LGT 4725 Каталог оборудования Liebherr (англ.)