CRYSTAL VENUS 46 VITRINE (CURVED) гнутое стекло [3/7] Thermostat figure 2

CRYSTAL VENUS 46 VITRINE (CURVED) гнутое стекло [3/7] Thermostat figure 2
3
In case of shutting the appliance off – either by the thermostat or due to power failure – and immediately
restarted, the compressor does not restart immediately. This is normal. The compressor will automatically start
soon after.
To protect your appliance, always wait for fifteen minutes before each restart.
Do not use electrical devices inside the food storage area of the appliance.
WARNING: we remind you that your appliance is a preserver for frozen products. It has not been
designed for the storage of products of ambient or higher temperature.
This appliance is not designed for use from the people (including children) with decreased physical, aesthetic
or intellectual abilities or with deficiency of experience and knowledge, unless they are under supervision or have
been given instructions concerning the appliance use from the person responsible for their safety.
The children have to be supervised in order to avoid playing with the device.
6. THERMOSTAT (Figure 2)
The thermostat located on the left side of your appliance, automatically sets the temperature inside the freezer
so that it varies from the warmer to the colder. The thermostat position is set and controlled by our company.
Based on the ambient temperature and on the refrigerator class for which the freezer has been designed, the
thermostat can be adjusted properly to ensure a temperature lower or equal to –15
0
C at the load line. It is
recommended to set the thermostat approximately in the middle of 3-4 range.
Turning the thermostat adjustment knob from position 1 to position 7, results in colder temperatures inside
the appliance.
7. INDICATION LAMP (EXCEPT FOR MODEL VETRINE 16)
The indication lamp is located at the front side of your appliance and it is on only when the freezer’s power
cable is connected.
If the indication lamp is off and the appliance is working, that means that the lamp is damaged and should be
replaced.
If the lamp is off and your appliance is not working, check whether:
¾ The plug is not properly inserted in the socket.
¾ There is power supply network failure.
8. LIGHTING SWITCH ON/OFF
The lighting switch is located at the side of the fluorescent lamp, at the show case.
This switch in on-off, meaning it controls whether the lamp will work (on position) or not
(off position).
9. THERMOMETER (EXCEPT FOR MODEL VETRINE 16)
The cylindrical thermometer located at the front side of your appliance, indicates the temperature inside the
freezer.
When the thermostat is set to 0 (off) the appliance is
switched off. Such an action is not recommended. If
you wish to deactivate your appliance simply unplug it.
Figure 2