Mitsubishi Electric MFZ-KA35VA / SUZ-KA35VA [10/30] Maintenance
![Mitsubishi Electric MFZ-KA35VA / SUZ-KA35VA [10/30] Maintenance](/views2/1324260/page10/bga.png)
10
WHEN THE AIR CONDITIONER IS NOT GOING TO BE
USED FOR A LONG TIME
When it is not going to be used for a long
time:
1 Perform the FAN operation for 3 or 4 hours
to dry the inside of the air conditioner.
• To perform FAN operation, set the remote control-
ler to the highest temperature in the MANUAL COOL
mode. (Refer to page 7.)
2 Turn off the breaker and/or disconnect the
power supply plug.
CAUTION:
Turn off the breaker or disconnect the power supply plug
when the air conditioner is not going to be used for a
long time.
Dirt may collect and this may cause a fire.
3 Remove the batteries from the remote con-
troller.
CAUTION:
To prevent liquid leakage, take out all batteries when the
remote controller is not going to be used for a long time.
When the air conditioner is to be used
again:
1 Clean the air filter and install it in the indoor
unit.
(Refer to page 10 for cleaning instructions.)
2 Check that the air inlet and outlet of the in-
door/outdoor units are not blocked with any
obstacles.
3 Check that the earth is connected correctly.
CAUTION:
Earth the unit.
Do not connect the earth to a gas pipe, water pipe, light-
ning rod or the earth of a telephone. If the earthing is
incorrect, it may cause an electric shock.
MAINTENANCE
Before starting maintenance
■
Turn off the breaker and/or disconnect the
power supply plug.
CAUTION:
When the unit is to be cleaned, switch it off and discon-
nect the power supply plug or turn off the breaker. Since
the fan rotates at high speed during operation, it may
cause an injury.
Cleaning the indoor unit
■
Clean the unit using a soft dry cloth.
• If the dirt is noticeable, wipe the unit with a cloth
soaked in a solution of mild detergent diluted in luke-
warm water.
• Do not use gasoline, benzine, thinner, polishing pow-
der, or insecticide. The unit may be damaged.
TIMER OPERATION (ON/OFF TIMER)
It is convenient to set the timer when you go to bed, when you get home, when you get up, etc.
How to set the ON timer
1 Press the
START
button during operation.
Each time the button is pressed, the ON timer mode
alternates between ON and OFF.
2 Set the time of the timer using the TIME but-
tons (Forward) and (Backward).
Each time the button is pressed, the set time
increases by 10 minutes; each time the
button is
pressed, the set time decreases by 10 minutes.
To release the ON timer:
■
Press the
START
button.
How to set the OFF timer
1 Press the
STOP
button during operation.
Each time the button is pressed, the OFF timer mode
alternates between ON and OFF.
2 Set the time of the timer using the TIME but-
tons (Forward) and (Backward).
Each time the button is pressed, the set time in-
creases by 10 minutes; each time the
button is
pressed, the set time decreases by 10 minutes.
To release the OFF timer:
■
Press the
STOP
button.
Programming timer operation
The ON timer and the OFF timer can be used in combination. The timer of the set time that is reached first will operate first.
(“ ” mark indicates the order of timer operations.)
• If the current time has not been set, the timer operation cannot be used.
NOTE:
If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled. As these models are equipped with an auto restart function, the air conditioner starts operating with timer
cancelled at the same time that power is restored.
HM05B040_MFZ-KA_en.p65 05.4.6, 7:12 PM10
Содержание
- Indoor unit 1
- Mfz ka25va mfz ka35va mfz ka50va 1
- Operating instructions 1
- Caution 2
- Contents 2
- Safety precautions 2
- Warning 2
- Caution 3
- For installation 3
- Indoor unit 3
- Outdoor unit 3
- Safety precautions name of each part 3
- Warning 3
- Auto restart function 4
- Name of each part 4
- Outdoor unit 4
- Preparation before operation 4
- Remote controller 4
- Preparation before operation 5
- Remote controller 5
- When the remote controller cannot be used emergency operation 5
- Auto changeover auto mode operation 6
- Description of auto changeover 6
- Description of auto restart function 6
- Details of display on the indoor unit 6
- Information for multi system air conditioner 6
- Operation indicator lamp 6
- To select the auto mode 6
- To stop operation 6
- Air flow velocity and direction adjustment 7
- Manual operation cool dry heat 7
- To select the cool dry or heat mode 7
- To stop operation 7
- Air flow velocity and direction adjustment 8
- Air outlet selection 8
- Description of operation 8
- How to set to blow out air from the upper air outlet only 8
- How to set to blow out air from the upper and lower air outlets 8
- Set the air outlet selection switch to 8
- To change the horizontal direction of the air flow move the vertical vane manually movement of the horizontal vane 8
- With this function air comes out simultaneously from the upper and lower air outlets so that the room can be cooled or heated effectively this function is set using the switch behind the front grille of the indoor unit this function is available in cooling and heating operation 8
- Econo cool operation 9
- I save operation 9
- Perform the following operations while the unit is operat ing in the manual cool mode 9
- To cancel i save operation 9
- To release the econo cool operation 9
- To set the temperature fan speed and air flow direction for i save operation 9
- To start i save operation 9
- Before starting maintenance 10
- Cleaning the indoor unit 10
- How to set the off timer 10
- How to set the on timer 10
- Maintenance 10
- Timer operation on off timer 10
- To release the off timer 10
- To release the on timer 10
- When it is not going to be used for a long time 10
- When the air conditioner is not going to be used for a long time 10
- When the air conditioner is to be used again 10
- Cleaning the catechin air filter 11
- Cleaning the catechin air filter about once every 2 weeks 11
- Cleaning the front grille 11
- Front grille 11
- Air cleaning filter 12
- Air cleaning filter replacement about once every year 12
- Cleaning the 12
- Cleaning the air cleaning filter about once every 3 months 12
- Replacement of the air cleaning filter 12
- Before contacting the service repre sentative check the following again 13
- When you think that trouble has occurred 13
- Disposal 14
- Electrical work 14
- Guaranteed operating range 14
- Inspection and maintenance 14
- Installation place 14
- Installation relocation and inspection 14
- Operating sound considerations 14
- Rating condition 14
- Relocation 14
- Specifications 14
- Меры предосторожности 15
- Осторожно 15
- Предупреждение 15
- Содержание 15
- Внутренний прибор 16
- Меры предосторожности названия отдельных частей прибора 16
- Наружный прибор 16
- Осторожно 16
- Предупреждение 16
- При установке прибора 16
- Названия отдельных частей прибора 17
- Наружный прибор 17
- Подготовка прибора к эксплуатации 17
- Пульт дистанционного управления 17
- Функция автозапуска 17
- Подготовка прибора к эксплуатации 18
- Пульт дистанционного управления 18
- Автоматическое переключение режимов работа в режиме auto 19
- Для остановки работы прибора 19
- Индикаторная лампочка работы 19
- Индикация на внутреннем приборе 19
- Информация в отношении мультисистемных кондиционеров воздуха 19
- Описание переключение режимов auto changeover 19
- Описание функции автозапуска 19
- Чтобы выбрать режим auto 19
- Для выбора режимов cool охлаждение dry сушка или heat обогрев 20
- Для остановки работы прибора 20
- Регулирование скорости и направления воздушного потока 20
- Ручное управление режимами охлаждение сушка обогрев 20
- Выбор выходного воздушного отверстия 21
- Как задать подачу воздуха из верхнего и нижнего выходных воздушных отверстий 21
- Регулирование скорости и направления воздушного потока 21
- Нажмите кнопку 22
- Работа в режиме i save 22
- Функция энергосбережения при охлаждении econo cool 22
- Чтобы задать необходимую скорость вентилятора 22
- Для выхода из режима таймера включения 23
- Для выхода из режима таймера выключения 23
- До начала чистки прибора 23
- Как настроить таймер включения 23
- Как настроить таймер выключения 23
- Когда вы не собираетесь пользоваться кондиционером длительное время 23
- Когда вы собираетесь отключить кондиционер на длительное время 23
- Работа с использованием таймера таймер включения выключения 23
- Уход за прибором 23
- Чистка внутреннего прибора 23
- Очистка катехинового воздушного фильтра 24
- Очистка катехинового воздушного фильтра каждые две недели 24
- Очистка передней решетки 24
- Передняя решетка 24
- Замена фильтра очистки воздуха 25
- Замена фильтра очистки воздуха примерно один раз в год 25
- Очистка фильтра очистки воздуха 25
- Очистка фильтра очистки воздуха примерно один раз в 3 месяца 25
- Если вам кажется что прибор неисправен 26
- Перед обращением в сервисную службу еще раз проверьте следующее 26
- Гарантированный диапазон температур эксплуатации 27
- Место установки 27
- Осмотр и техническое обслуживание прибора 27
- Перемещение прибора в другое место 27
- Примите во внимание шум при работе прибора 27
- Расчетные условия эксплуатации 27
- Технические характеристики 27
- Установка перемещение и осмотр прибора 27
- Утилизация 27
- Электромонтажные работы 27
- Sg79y505h01 30
Похожие устройства
- Mitsubishi Electric MFZ-KA35VA / SUZ-KA35VA Брошюра
- Mitsubishi Electric MFZ-KA35VA / SUZ-KA35VA Руководство по установке
- Mitsubishi Electric SLZ-KA35VAL / SUZ-KA35VA Инструкция по эксплуатации
- Mitsubishi Electric SLZ-KA35VAL / SUZ-KA35VA Брошюра
- Mitsubishi Electric SLZ-KA35VAL / SUZ-KA35VA Руководство по установке
- Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA Инструкция по эксплуатации
- Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA Брошюра
- Mitsubishi Electric SEZ-KD35VAQ / SUZ-KA35VA Руководство по установке
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Инструкция по эксплуатации
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Брошюра
- Mitsubishi Electric SEZ-KD50VAQ / SUZ-KA50VA Руководство по установке
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Инструкция по эксплуатации
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Брошюра
- Mitsubishi Electric SLZ-KA50VAL / SUZ-KA50VA Руководство по установке
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Инструкция по эксплуатации
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Брошюра
- Mitsubishi Electric MSZ-HJ35VA / MUZ-HJ35VA Руководство по установке
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Инструкция по эксплуатации
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Брошюра
- Mitsubishi Electric MSZ-FH50VE / MUZ-FH50VE Руководство по установке