Elcold PRO 21 [15/18] Default setting values
![Elcold PRO 21 [15/18] Default setting values](/views2/1326321/page15/bgf.png)
User Instructions Low Temperature Freezers Model PRO/XLT
DEFAULT SETTING VALUES
14
Set
Hy1
LS1
US1
S1C
Ac
on
ono
Set point
Differential
Minimum set point
Maximum setpoint
Action type output
Anti-short cycle delay
Minimum time a stage stays switched ON
Minimum time between 2 following switching
ON of the same load
ALC
ALL
ALU
ALH
ALd
dAO
So1
tba¹
AS¹
Lci²
Uci²
OPb
rES
UdM
PbC
P3F
HES
i1F
i1P
did
Adr
OnF
Ptb
rEL
Pr2
Alarm configuration
Minimum alarm (ALC=rE)
(ALC=Ab)
Maximum alarm (ALC=rE)
(ALC=Ab)
Alarm recovery differential
Alarm delay
Alarm delay at start up
Output status with faulty pr.
Alarm relay disabling
Alarm relay polarity
Start scale with current or voltage input
End scale with current or voltage input
Probe calibration
Resolution
Measurement unit
(temp.)
(current/voltage)
Kind of probe
3rd wire presence
Energy saving differential
Digital inputconfiguration
Digital input polarity
Alarm delay for dig. input
Serial adress
oFF function enabling
Parameter table
Software release
To access the Pr2
LS1+US1
-Full Sc./Full Sc.
Down Sc./Set
Set/Full Sc.
in=Inverse; dir=directed
0 -250 sec.
0 -250 sec.
0 -120 min.
rE=relat.; Ab=absolute
0 +[Start Sc.-Set].
Start Sc.+ALu
0 +[Full Sc.-Set]
ALL+Full scale
0 -Full scale
0 -999 min
0 -23h 50 min
oFF=open on=closed
no; yES
CL + oP
-1999 -1999
-1999 -1999
-Full Sc./Full Sc.
in=NO; dE=0,1; cE=0,01
°C=°C; °F;
0=°C; 1=°F; 2=HR; 3=bar;
4=PSI; 5=off
PT=Pt100; J=tcJ; c=tck;
S=tcS; Ptc=PTC; ntc=NTC;
0-1=0-1V; 10=0+10V;
cur=0-20mA
no=2 wires;
yES=3wires
Down SC./Full Sc.
c-H/oFF/AuS/HES/EAL/bAL
cL=closed; oP=open
0-120 m
0-247
no=not enabled;
yES=enabled
Readable only
Readable only
Readable only
COD Name Range °C/°F Lev
0/32
-1/-2
min
max
in
0
0
0
rE
10.0/ 20
10.0/ 20
2.0/4
15
1.3
oFF
yES
oP
various
various
0.0
in
various
various
no
0.0
EAL
cL
0
1
no
--
--
321
-
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr1
Pr2
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Содержание
- Pro frost 2
- User instructions 2
- Default setting values 15
- 15 to 25 16
- 30 to 60 16
- Ambient temperature 16
- Depth excl handle and hinges 16
- Factory settings pro xlt models 16
- Height with 50 mm castors 16
- Height with open lid 16
- Insulation thickness 16
- Litres 16
- Net volume 16
- Noise level 16
- Power consumption at 25 c 16
- Pro 11 11 xlt pro 21 21 xlt pro 31 31 xlt pro xlt pro 60 60 xlt pro 41 41 xlt 16
- Technical specifications 16
- Temeprature range 16
- User instructions low temperature freezers model pro xlt 16
- Weight 16
- User instructions low temperature freezers model pro xlt 17
- Wiring diagrams 17
Похожие устройства
- Elcold PRO 21 Брошюра
- Elcold Focus 151 Red Инструкция по эксплуатации
- Elcold Focus 151 Red Брошюра
- Elcold Focus 151 Blue Инструкция по эксплуатации
- Elcold Focus 151 Blue Брошюра
- Elcold PRO 41 Инструкция по эксплуатации
- Elcold PRO 41 Брошюра
- Elcold Focus 171 Red Инструкция по эксплуатации
- Elcold Focus 171 Red Брошюра
- Neff N17HH11N0 Инструкция по эксплуатации
- Neff N17HH11N0 Инструкция по монтажу
- Elcold PRO 60 Инструкция по эксплуатации
- Elcold PRO 60 Брошюра
- Elcold Focus 171 Blue Инструкция по эксплуатации
- Elcold Focus 171 Blue Брошюра
- Bear Varimixer AR60 VL-1S Инструкция по эксплуатации
- Bear Varimixer AR60 VL-1S Каталог оборудования Bear Varimixer
- Elcold PRO 11 Инструкция по эксплуатации
- Elcold PRO 11 Брошюра
- Hoshizaki IM-240NE Инструкция по эксплуатации