La Nordica Isotta con cerchi Evo [17/88] In a emergency

La Nordica Giulietta X [17/88] In a emergency
VIOLETTA X / GIULIETTA X / ISETTA EVO / ISOTTA EVO / VIOLA EVO / ISOTTA FORNO
1195300 17
Installation must be carried out by authorised personnel who must provide the buyer with a system declaration of conformity and will
assume full responsibility for nal installation and as a consequence the correct functioning of the installed product.
The Product, assembled and ready for the installation, must be connected with a junction to the existing ue of the house. The junction
must be possibly short, straight, horizontal or positioned a little uphill. The connections must be tight.
Before installing the appliance, carry out the following checks:
UPPER smoke output - REAR - LATERAL
verify if your structure can support the weight of the appliance. In case of insufcient carrying capacity it is necessary to
adopt appropriate measures, La NORDICA responsibility is limited to the supply of the appliance (See chapter TECHNICAL
DESCRIPTION).
Make sure that the oor can support the weight of the appliance (for ex. distributing weight plate), and if it is made of ammable
material, provide suitable insulation (DIMENSIONS ACCORDING TO REGIONAL REGULATIONS).
Make sure that there is adequate ventilation in the room where the appliance is to be installed, with particular attention to windows
and doors with tight closing (seal ropes).
Do not install the appliance in rooms containing collective ventilation ducts, hoods with or without extractor, type B gas appliances,
heat pumps, or other appliances that, operating at the same time, can put the room in depression (ref. UNI 10683 standard).
Make sure that the ue and the pipes to which the appliance will be connected are suitable for its operation. It is NOT allowed the
connection of various appliances to the same chimney.
The diameter of the opening for connection to the chimney must at least correspond to the diameter of the ue gas pipe. The
opening must be equipped with a wall connection for the insertion of the exhaust pipe and a rosette.
The unused ue gas exhaust stub pipe must be covered with its respective cap (see chapter DIMENSIONS).
The installation must be appropriate and has to allow the cleaning and maintenance of the product and the ue.
La NORDICA S.p.A. declines all responsibility for damage to things and/or persons caused by the system. In addition, it is not
responsible for any product modied without authorisation and even less for the use of non original spare parts.
Your regular local chimney sweep must be informed about the installation of the appliance so that he can check the correct connection to
the chimney.
4. FIRE SAFETY
When installing the product, the following safety measures must be observed:
a) In order to ensure sufcient thermal insulation, respect the minimum safety distance from objects or furnishing components
ammable and sensitive to heat (furniture, wood sheathings, fabrics. etc.) and from materials with ammable structure (see
Picture 4 at page 61 - A). All the minimum safety distances are shown on the product data plate and lower values must not
be used.
b) In front of the furnace door, in the radiation area there must be no ammable or heat-sensitive objects or material at a distance of
less than 100 120 cm. This distance can be reduced to 40 cm where a rear-ventilated, heat-resistant protection device is installed
in front of the whole component to protect.
c) If the product is installed on a non totally refractory oor, one must foresee a reproof background. The oors made of inammable
material, such as moquette, parquet or cork etc., must be covered by a layer of no-inammable material, for instance ceramic,
stone, glass or steel etc. (size according to regional law). The base must extend at least 50 cm at the front and at least 30 cm at
the sides, in addition to the opening of the loading door (see Picture 4 at page 61 - B).
d) No ammable components (e.g. wall units) must be present above the product.
The Product must always operate exclusively with the ash drawer inserted. The solid combustion residues (ash) must be collected in a
sealed, re resistant container. The Product must never be on in the presence of gaseous emissions or vapours (for example glue for
linoleum, petrol etc.). Never deposit ammable materials near the Product.
During combustion, thermal energy is released which leads to considerable heating of the surfaces, doors, handles, controls, glass parts,
the ue gas pipe and possibly the front part of the appliance. Avoid contact with these elements unless using suitable protective
clothing or accessories (heat resistant gloves, control devices).
Ensure children are aware of these dangers and keep them away from the furnace when it is on.
When using the wrong fuel or one which is too damp, due to deposits present in the ue, a ue re is possible.
4.1. IN A EMERGENCY
If there is a re in the ue connection :
a) Close the loading door and the ash drawer door
b) Close the comburent air registers
c) Use carbon dioxide ( CO
2
powder ) extinguishers to put out the re
d) Request the immediate intervention of the Fire Brigade
DO NOT PUT OUT THE FIRE WITH WATER.
When the ue stops burning, have it checked by a specialist to identify any cracks or permeable points.