CARILLON 4:3 – CARILLON 16:9 – CARILLON CLASSIC
20 7196755 – EN
Picture 6
Picture 7
Picture 8
CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683/98
Inclination of the roof
Distance between the roof ridge
and the stack
Minimum height of the stack (measured from the
outlet)
α
αα
α
A (m) H (m)
15°
< 1,85 m 0,50 m above the roof ridge
> 1,85 m 1,00 m from the roof
30°
< 1,50 m 0,50 m above the roof ridge
> 1,50 m 1,30 m from the roof
45°
< 1,30 m 0,50 m above the roof ridge
> 1,30 m 2,00 m from the roof
60°
< 1,20 m 0,50 m above the roof ridge
> 1,20 m 2,60 m from the roof
(1) The chimney cap must not show hindrances within 10 m from walls,
pitches and trees. Otherwise raise it of at least 1 m over the hindrance.
The chimney cap must exceed the ridge of the roof of at least 1 m.
2 m
10 m
1
m
>
_
A
>A
0,5 m
H min.
α
(2)roof
(1)ridge axis
50 cm
(1) In case of flues side by side, a chimney cap must be
higher than the other one of at least 50 cm in order to avoid
pressure transfers between the flues themselves.