La Nordica TermoRosa D.S.A бордовая [23/88] Chimney pot

La Nordica TermoRosa D.S.A натуральный камень [23/88] Chimney pot
“TERMOROSA - DSA”
“7097501” 23
C - FLUE GAS Register (Picture 7 at page 84)
(Conversion from the cookerHOTPLATEUSEOVENUSE function to the cooker HEATINGfunction)
On the right of the front of the stove/cooker, between the protection rail and the oven door, is the smoke-register control lever, recognisable
as a bronze knob. When the lever is pushed towards the back of the stove/cooker, the combustion gases ow above the oven directly
towards the exhaust stub (cooker function – PLATE USE); when the lever is pulled towards you, the combustion gases ow all around
the oven, so the internal temperature increases evenly (cooker – oven cooking and heating – OVEN USE).
To ignite the ame follow the instructions below (see Cap. IGNITION) :
Open the ignition register to aid ue gas exhaust. Position the register (any buttery valve placed on the ue gas exhaust pipe must
also be opened).
Position the thermostat knob on position 5 (maximum opening).
Open the primary air register (placed on the ash tray).
After having started the re with small pieces of wood and waited until it is well lit, adjust the thermostat to the positions corresponding
to the desired heat (0÷5).
Bring the ue gas register to the oven position.
Close the any buttery valve placed on the ue gas exhaust pipe must also be opened.
The register regulation necessary in order to obtain nominal caloric output is the following (see Cap. TECHNICAL DATA):
Hourly consumption in kg / h PRIMARY air Register SECONDARY air Register TERTIARY air
4,5 CLOSED OPEN PRE-ADJUSTED
6. FLUE
Essential requirements for correct appliance operation:
the internal section must preferably be circular;
the appliance must be thermally insulated and impermeable and built with suitable materials which are resistant to heat, combustion
products and any condensation;
there must be no narrowing and vertical passages with deviations must not be greater than 45°;
if already used, it must be clean;
the technical data from the instruction manual must be respected;
If the ues are of a square or rectangular section, the internal edges must be rounded with a radius of not less than 20 mm.
For the rectangular section, the maximum ratio between the sides must be ≤ 1.5.
A section which is too small causes a reduction in draught. A minimum height of 4 m is advisable.
The following materials are FORBIDDEN and compromise the good operation of the appliance: asbestos cement, galvanised steel, rough
and porous internal surfaces. Picture 2 at page 81 shows some example solutions.
The minimum section must be 4 dm
2
(for example 20x20 cm) for appliances whose pipe dimensions are less than 200 mm, or 6.25
dm
2
(for example 25x25 cm) for appliances with a diameter of more than 200 mm.
The draught created by your ue must be sufcient but not excessive.
A section of the ue which is too large can present a volume which is too large to heat and therefore cause operating difculties for the
appliance; to avoid this, it is necessary to intubate the appliance for its entire height. A section which is too small causes a reduction in
draught.
ATTENTION: as far as concern the realisation of the ue connection and ammable materials please follow the requirements provided by
UNI 10683 standard. The ue must be at a suitably distance from ammable or combustible material using suitable insulation or
an air space.
It is FORBIDDEN to pass system piping or air ducts inside the ue. It is also forbidden to create moveable or xed openings on the ue
itself, for the connection of further different appliances (See chapter CONNECTING A FIREPLACE OR OPEN HEARTH TO THE FLUE).
6.1. CHIMNEY POT
The ue draught depends on the suitability of the chimney pot.
It is therefore essential that, if built in a handcrafted way, the exit section is more than twice the internal section of the ue
(Picture 3 at page 81) .
As it must always go past the ridge of the roof, the chimney pot must ensure exhaust even in the presence of wind (Picture 4 at page 82).
The chimney pot must meet the following requirements:
Have an internal section equivalent to that of the chimney.
Have a useful exit section of double the internal section of the ue.
Be built so as to prevent rain, snow or any foreign body entering the ue.
Be easy to inspect, for any maintenance and cleaning operations.